To use the UDx75 software with a modem connection:
1.
Follow steps 1 - 5 on page 16.
2.
Make sure that the modem settings are correct. For more information about modem
settings, see the
UDx75 Online Help
.
3. Select
Download>Connect> Connect Using AMD
.
4.
A message box opens saying
Initializing modem
.
5.
The computer connects to the panel.
6.
When you are finished uploading or downloading, select
Download>Disconnect
or
click the
Disconnect
icon.
4.3 Programming
with
up/download software
Downloading allows you to read the existing programming data or the event log from the
control panel. Uploading allows you to send programming data, that you have set up
using the UDx75 software, from the computer to the control panel.
Before you download or upload information, do the following:
1.
Ensure that the relevant control panel options are programmed correctly. There are
a minimum number of options that you must set before you can program the control
panel using the up/download software. Table 2 lists the options and the values to
enter.
2.
Ensure that the up/download access code is the same in both the up/download
software and the control panel. See Table 1 for the correct default code.
3.
If you are connecting remotely, make sure that the modem settings are correct. For
more information about modem settings, see the
UDx75 Online Help
.
4.
Connect to the panel via the serial port or modem.
5. Select
Download>Read all
to download all the data from the control panel. The
computer downloads the data from the panel.
6. Select
Download>Send all
to upload all the data to the control panel. The computer
uploads the data to the panel.
The data that is downloaded and the downloading speed depend on the
Send All/Read
All
settings. The default number of strings sent to the keypad is 192 but it is possible to
limit the number of strings sent. If the default number is reduced, download time
decreases. For more information on setting up/download options, see the
UDx75 Online
Help
.
Keypad menu option
Value
Serial Port>Connection Type
Home Automation
Serial Port>Speed
9600 Baud
Home Automation>Protocol
Binary
Home Automation>Transition Broadcasts
Ensure all options are set to
Off
. This is the default state.
Home Automation>Commands/Requests
Ensure all options are set to
On
. This is the default state.
Table 2 Required settings for up/downloading