Chapter 3: Programming
Concord 4 Installation Manual
67
Edit sensors
Shortcut: 083
Default: None
This menu lets you view and, if desired, change the group and partition
assignment for each learned zone or sensor. For example, the display
shows:
S01 P1 G13 NC HW BACK DOOR
.
Where S01 is the zone/sensor number, P1 is partition 1, G13 is sensor group
13, NC is normally closed, HW is hardwired, and BACK DOOR is the
programmed text name.
Other description codes include:
• RF (wireless sensor)
• TP
(touchpad)
• NO
(normally
open)
To edit sensors:
1. Press A
or B until the display shows
EDIT SENSORS
.
2. Press #
and the display shows the sensor or zone with the lowest number.
3. Press A or B to scroll through all learned zones and sensors.
4. When the desired zone or sensor is displayed, press #
.
The display shows
SENSOR PTN n
(current partition assignment).
5. Enter the desired partition number, then press #. The display shows the
new partition assignment.
6. Press A
or B
and the display shows
SENSOR GROUP nn
(current group
assignment).
7. Enter the desired group number, then press #. The display shows the new
group assignment.