Chapter 3: Programming
44
Concord 4 Installation Manual
Multipartition
arm/disarm
Shortcut: 0004
Default: Off. Partition to
turn on
This feature controls which partitions (1 to 6) can be armed/disarmed
simultaneously when using a touchpad and access code assigned to
those partitions. When enabled, users can arm/disarm selected partitions
using an authorized access code. When disabled, multiple partitions
cannot be armed/disarmed simultaneously. For this feature:
• At least two partitions must be selected.
• Touchpads must be assigned to at least one of the selected partitions of
this menu.
• Access codes must be assigned to all selected partitions of this menu. If
the partition assignment for a specific access code does not match the
partitions selected in this menu, only those partitions common to both
menu settings can be armed/disarmed simultaneously with that code.
• A partition cannot be armed/disarmed if it is being controlled by another
source at that time.
• All arming modifiers except Silent affect all partitions being armed. Only
the arming partition can be armed silently.
• When arming multiple partitions, any conditions that prevent arming
are identified on touchpad displays with the affected partition number
flashing. The normal protest/auto force arm sequence follows, or pressing
*
cancels the arming request.
• When disarming multiple partitions, any partitions in alarm have the
affected partition number flashing on touchpad displays. Pressing #
cancels all alarms in the selected partitions. Alarm memory information is
then displayed for all canceled alarms.
To disable mulitipartition arm/disarm, with the display showing
MULTI-
PTN ARM/DISARM n n n n n n n
, select all of the partitions by
entering the appropriate partition number. The partition numbers
disappear from the display. Press #.