Appendix B: Reference tables
Concord 4 Installation Manual
125
# Name
Application
Alarm Delay
Restoral
Supervisory
CS Report
Chime (Le
vel)
Acti
ve
le
ve
ls
12 Entry/
exit delay
Driveway gates and
entrances that require a
twice extended delay time.
Police Twice
extended
2,3
13 Instant
perimeter
Exterior doors and windows Police
Instant
2, 3
14 Instant
interior
Interior doors (Hardwired)
Police
Follower
2,3
15 Instant
interior
Interior PIR motion sensors.
(RF wireless)
Police Follower
2,3
16 Instant
interior
Interior doors. (Hardwired)
Police
Follower
3
17 Instant
interior
PIR motion sensors (RF
wireless.)
Police
Follower
3
18 Instant
interior
Instant interior cross-zone#
PIR motion sensors. *
Police Follower
3
19 Delayed
interior
Interior doors that initiate a
delay before going into
alarm.
Police Interior
3
20 Delayed
interior
PIR motion sensors that
initiate a delay before going
into alarm.
Police Standard
3
21 Local
instant
interior
24-hour local alarm zone
protecting anything that
opens and closes.
Police Instant
1,2,3
22 Local
delayed
interior
Same as group 21, plus
activation initiates a delay
before going into alarm.
Police Standard
1,2,3
23 Local
instant
auxiliary
24-hour local alarm zone
protecting anything that
opens and closes.
Auxiliary Instant
1,2,3
24 Local
instant
auxiliary
24-hour local alarm zone
protecting anything that
opens and closes. Sirens
shut off at restoral.
Auxiliary Instant
1,2,3
25 Local
special
chime
Notify the user when a door
is opened. Sounds emit from
a local annunciator.
Special
chime
Instant
1,2,3
26 Fire
24-hour fire, rate-of-rise
heat, and smoke sensors.
Fire Instant
1,2,3