background image

Air direction on the indoor side is

Air direction on the outdoor side is

through 

 front grille and out the

through the rear grille and out

top. Air flow out the top should not

through the top and side louvers.

be obstructed by curtains or drapes.

The top grille has 3 settings to 
you vary the angle of the air
discharge. Grasp tabs on 

 end

and pull it up until the top 
stops at the setting you want.

User 

 

 

 r 

 

 air conditioner off and

remove plug from wall receptacle
before cleaning.

   

Wipe grilles with a clean cloth
lightly dampened with mild liquid

 detergent. Wash

cabinet with mild soap or detergent
and lukewarm water.

 

 

These coils on the weather side
of the unit should be checked
periodically and cleaned if clogged
with dirt or soot from the atmosphere.
If extremely soiled, they may need
to be steam cleaned, a service
available through your General
Electric service outlet.

 

The foam air filter behind the

inlet grille should be washed at
least every 30 days or as often as
it needs cleaning.

II

Remove the inlet grille by grasping

the tab at the top of the grille, pulling
out and lifting grille out.

Place the grille on a flat surface
and remove the filter. Wash the
filter in hot, soapy water, just as
you would a sponge. Squeeze dry.

To reinstall the filter, place it on
pins located on the back side of
the grille.

To replace the grille, place the two
tabs at the bottom of the grille into
slots on the case and push the grille

forward.

5

Pub. 

 49-7162-0

Summary of Contents for Carry-Cool ATM04

Page 1: ...bt ffim Use and Care of Carry Cool models ATM04 ATM05 ATM06 Energy saving tips pi Operating the controls p4 Air direction p5 How to clean the air filter p5 Questions Use the Problem Solver p6 q G E N ERAL E lECTRI C ...

Page 2: ...more help write include your phone number Consumer Affairs General Electric Company Appliance Park Louisville KY 40225 Write down the model and serial numbers You ll find them on a label on the frame of the air conditioner behind the air filter These numbers are also on the Consumer Product Ownership Registration Card that came with your air conditioner Before sending in this card please write the...

Page 3: ...al hardware stores TEMPORARY METHOD The larger slot in the adapter must be aligned with the larger slot in the til outlet to provide proper polarity in the connection of the power cord UTfON Attaching an adapter ground terminal to wall outlet cover screw does not ground appliance unless cover screw is metal and not insulated and wall outlet is groundd through house wiring You should have circuit c...

Page 4: ...lector Switch at LO COOL 2 Set Temperature Control at desired number When the Temperature Control is set on 9 or 10 and the Fan is set on low speed moisture may freeze on the coils and prevent the unit from cooling If this happens set the Fan at high speed and set the Temperature Control to a lower number lJor air C it culatiotl atld f iitet itlg titllout C lillg Set the Selector Switch at LO FAN ...

Page 5: ...r detergent and lukewarm water OIl ieiIst r CU ils These coils on the weather side of the unit should be checked periodically and cleaned if clogged with dirt or soot from the atmosphere If extremely soiled they may need to be steam cleaned a service available through your General Electric service outlet Air E ilter The foam air filter behind the inlet grille should be washed at least every 30 day...

Page 6: ... to cool down Cold air maybe escaping through open furnace floor registers and cold airretums Vent Control maybe set at open position allowing hot outside air to enter the room Cooling coils have iced up To melt ice set the Fan at high speed and the Temperatu Control to a lower number Thermostat click a metallic sound maybe heard when the compressor cycles on and off This is normal Fan runs contin...

Page 7: ...rther help FIRST contact the people who serviced your appliance Explain why you are not pleased In most cases this will solve the problem NEXT if you are still not pleased write all the details including your phone number to Manager Consumer Relations General Electric Appliance Park Louisville Kentucky 40225 FINALLY if your problem is still not resolved write Major Appliance Consumer Action Panel ...

Page 8: ...ne directory for GENERAL ELECTRIC COMPANY GENERAL ELECTRIC FACTORY SERVICE GENERAL ELECTRIC HOTPOINT FACTORY SERVICE or GENERAL ELECTRIC CUSTOMER CARE SERVICE WHAT IS NOT COVERED lmProPer installation c Failure of the product resulting from If you have an installation problem modifications to the product or due to or if the air conditioner is of unreasonable use including failure to improper cooli...

Reviews: