. Keep the air filter clean. (See

instructions on page 5.)

● 

For most efficient cooling, keep

vent in closed position except when
you want to exhaust air, smoke or
odors from the room.

● 

Don’t let the room get too

hot. Whenever possible, turn the
unit on before the room heats up.
When heat is “stored up” in walls,
furniture, rugs and draperies, your
air conditioner takes longer to
produce the desired comfort
condition.

. Keep windows and doors

closed. Cool, dry air escapes when
they’re open.

● 

Keep furnace floor registers and

cold air returns closed. Cold air
can easily escape through them.

● 

Don’t let drapes or furniture block

top or front of unit and restrict air
flow when it is operating.

● 

It’s best to operate your air

conditioner at high speed during
extremely hot weather.

● 

Keep outdoor condenser coil

clean. (See page 5.)

● 

Turn air conditioner off before

vacations or extended absences

from home.

 

 YOU. . .

Before using your
air conditioner, read

this book carefully.

It is intended to help you operate
and maintain your new air
conditioner properly.

Keep it handy for answers to your
questions.

If you don’t understand something
or need more help, write (include
your phone number):
Consumer Affairs
General Electric Company
Appliance Park
Louisville, KY 40225

Write down the model
and serial numbers.

You’ll find them on a label on the
frame of the air conditioner behind

the air filter.

These numbers 

 also on the

Consumer Product Ownership
Registration Card that came with
your air conditioner. Before sending
in this card, please write these
numbers here:

“Model Number

Serial Number

Use these numbers in any
correspondence or service calls
concerning your air conditioner.

If you received a damaged air
conditioner,  
immediately contact
the dealer (or builder) that sold you
the air conditioner.

Save time and money.
Before you request service, 
check
the Problem Solver on page 6. It
lists minor causes of operating
problems that you 

 correct

yourself.

2

 

 

Read all instructions before
using this appliance.

When using this appliance, always
exercise basic safety precautions,

including the following:

● 

Use this appliance only for its

intended purpose  as described in
this Use and Care Book.

● 

This air conditioner must be

properly installed in accordance
with the Installation Instructions

before it is used. See grounding

instructions on page 3.

● 

Never unplug your air conditioner

by pulling on the power cord.
Always grip plug firmly and pull
straight out from the receptacle.

● 

Repair or replace immediately

all electric service cords that
have become frayed or otherwise
damaged.  
Do not use a cord that
shows cracks or abrasion damage
along its length or at either the
plug or connector end.

SAVE THESE
INSTRUCTIONS

Summary of Contents for Carry-Cool ATM04

Page 1: ...bt ffim Use and Care of Carry Cool models ATM04 ATM05 ATM06 Energy saving tips pi Operating the controls p4 Air direction p5 How to clean the air filter p5 Questions Use the Problem Solver p6 q G E N ERAL E lECTRI C ...

Page 2: ...more help write include your phone number Consumer Affairs General Electric Company Appliance Park Louisville KY 40225 Write down the model and serial numbers You ll find them on a label on the frame of the air conditioner behind the air filter These numbers are also on the Consumer Product Ownership Registration Card that came with your air conditioner Before sending in this card please write the...

Page 3: ...al hardware stores TEMPORARY METHOD The larger slot in the adapter must be aligned with the larger slot in the til outlet to provide proper polarity in the connection of the power cord UTfON Attaching an adapter ground terminal to wall outlet cover screw does not ground appliance unless cover screw is metal and not insulated and wall outlet is groundd through house wiring You should have circuit c...

Page 4: ...lector Switch at LO COOL 2 Set Temperature Control at desired number When the Temperature Control is set on 9 or 10 and the Fan is set on low speed moisture may freeze on the coils and prevent the unit from cooling If this happens set the Fan at high speed and set the Temperature Control to a lower number lJor air C it culatiotl atld f iitet itlg titllout C lillg Set the Selector Switch at LO FAN ...

Page 5: ...r detergent and lukewarm water OIl ieiIst r CU ils These coils on the weather side of the unit should be checked periodically and cleaned if clogged with dirt or soot from the atmosphere If extremely soiled they may need to be steam cleaned a service available through your General Electric service outlet Air E ilter The foam air filter behind the inlet grille should be washed at least every 30 day...

Page 6: ... to cool down Cold air maybe escaping through open furnace floor registers and cold airretums Vent Control maybe set at open position allowing hot outside air to enter the room Cooling coils have iced up To melt ice set the Fan at high speed and the Temperatu Control to a lower number Thermostat click a metallic sound maybe heard when the compressor cycles on and off This is normal Fan runs contin...

Page 7: ...rther help FIRST contact the people who serviced your appliance Explain why you are not pleased In most cases this will solve the problem NEXT if you are still not pleased write all the details including your phone number to Manager Consumer Relations General Electric Appliance Park Louisville Kentucky 40225 FINALLY if your problem is still not resolved write Major Appliance Consumer Action Panel ...

Page 8: ...ne directory for GENERAL ELECTRIC COMPANY GENERAL ELECTRIC FACTORY SERVICE GENERAL ELECTRIC HOTPOINT FACTORY SERVICE or GENERAL ELECTRIC CUSTOMER CARE SERVICE WHAT IS NOT COVERED lmProPer installation c Failure of the product resulting from If you have an installation problem modifications to the product or due to or if the air conditioner is of unreasonable use including failure to improper cooli...

Reviews: