background image

Questions’?
Use This Problem 

PROBLEM

AIR CONDITIONER
DOES NOT OPERATE

AIR CONDITIONER

“DOES 

 COOL

AS IT SHOULD”

OPERATING SOUNDS

WATER DRIPPING
OUTSIDE

WATER 
INSIDE

WATER IN BASE PAN
(ON OUTDOOR SIDE)

POSSIBLE CAUSE AND REMEDY

● 

Not plugged in. Plug may have been bumped loose by vacuum cleaner or furniture.

● 

If plugged in, fuse could have blown or circuit breaker may have tripped.

● 

Curtain, blinds or furniture blocking the top or the front of the air conditioner will

restrict air flow.

● 

Temperature Control may not be set high enough. Turn knob to a higher number.

Highest setting should provide maximum cooling.

● 

Air 

 dirty, should be cleaned at least every 30 days. See instructions, page 5.

. Room may have been very hot when air conditioner was first turned on. Allow time
for it to cool down.

● 

Cold air maybe escaping through open furnace floor registers and cold 

● 

Vent Control maybe set at open position, allowing hot outside air to enter the room.

● 

Cooling coils have iced up. To melt ice, set the Fan at high speed and the 

Control to a lower number.

● 

Thermostat click, a metallic sound, maybe heard when the compressor cycles  on and

off. This is normal.

● 

Fan runs continuously when Selector is in Cool or Fan position. This is normal.

● 

Excess water may overflow in excessively hot and humid weather. This is normal.

● 

Air conditioner must be installed 

 or tilted slightly to the outside for proper

water disposal.

● 

This is normal for a short period in areas with little humidity; normal for a longer

period in very humid areas. Moisture removed from indoor air drains to rear of cabinet
where it is picked up by a fan and thrown against the outdoor condenser coil.

If 

 need more help.. call, toll free:

The 

GE Answer 

consumer information service

6

Summary of Contents for Carry-Cool ATM04

Page 1: ...bt ffim Use and Care of Carry Cool models ATM04 ATM05 ATM06 Energy saving tips pi Operating the controls p4 Air direction p5 How to clean the air filter p5 Questions Use the Problem Solver p6 q G E N ERAL E lECTRI C ...

Page 2: ...more help write include your phone number Consumer Affairs General Electric Company Appliance Park Louisville KY 40225 Write down the model and serial numbers You ll find them on a label on the frame of the air conditioner behind the air filter These numbers are also on the Consumer Product Ownership Registration Card that came with your air conditioner Before sending in this card please write the...

Page 3: ...al hardware stores TEMPORARY METHOD The larger slot in the adapter must be aligned with the larger slot in the til outlet to provide proper polarity in the connection of the power cord UTfON Attaching an adapter ground terminal to wall outlet cover screw does not ground appliance unless cover screw is metal and not insulated and wall outlet is groundd through house wiring You should have circuit c...

Page 4: ...lector Switch at LO COOL 2 Set Temperature Control at desired number When the Temperature Control is set on 9 or 10 and the Fan is set on low speed moisture may freeze on the coils and prevent the unit from cooling If this happens set the Fan at high speed and set the Temperature Control to a lower number lJor air C it culatiotl atld f iitet itlg titllout C lillg Set the Selector Switch at LO FAN ...

Page 5: ...r detergent and lukewarm water OIl ieiIst r CU ils These coils on the weather side of the unit should be checked periodically and cleaned if clogged with dirt or soot from the atmosphere If extremely soiled they may need to be steam cleaned a service available through your General Electric service outlet Air E ilter The foam air filter behind the inlet grille should be washed at least every 30 day...

Page 6: ... to cool down Cold air maybe escaping through open furnace floor registers and cold airretums Vent Control maybe set at open position allowing hot outside air to enter the room Cooling coils have iced up To melt ice set the Fan at high speed and the Temperatu Control to a lower number Thermostat click a metallic sound maybe heard when the compressor cycles on and off This is normal Fan runs contin...

Page 7: ...rther help FIRST contact the people who serviced your appliance Explain why you are not pleased In most cases this will solve the problem NEXT if you are still not pleased write all the details including your phone number to Manager Consumer Relations General Electric Appliance Park Louisville Kentucky 40225 FINALLY if your problem is still not resolved write Major Appliance Consumer Action Panel ...

Page 8: ...ne directory for GENERAL ELECTRIC COMPANY GENERAL ELECTRIC FACTORY SERVICE GENERAL ELECTRIC HOTPOINT FACTORY SERVICE or GENERAL ELECTRIC CUSTOMER CARE SERVICE WHAT IS NOT COVERED lmProPer installation c Failure of the product resulting from If you have an installation problem modifications to the product or due to or if the air conditioner is of unreasonable use including failure to improper cooli...

Reviews: