IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric 

shock or personal injury.

„

Use this appliance only for its intended 

purpose as described in this Owner’s 

Manual. 

„

This air conditioner must be properly 

installed in accordance with the Installation 

Instructions before it is used. 

„

Never unplug your air conditioner by pulling 

on the power cord. Always grip plug firmly 

and pull straight out from the receptacle. 

„

Replace immediately all electric service 

cords that have become frayed or otherwise 

damaged. A damaged power supply cord 

must be replaced with a new power supply 

cord obtained from the manufacturer and 

not repaired. Do not use a cord that shows 

cracks or abrasion damage along its length  

or at either the plug or connector end. 

„

Turn the unit 

OFF

 and unplug your air 

conditioner before cleaning. 

„

GE does not support any servicing of the 

air conditioner. We strongly recommend 

that you do not attempt to service the air 

conditioner yourself.

„

For your safety…do not store or use 

combustible materials, gasoline or other 

flammable vapors or liquids in the vicinity  

of this or any other appliance.

„

All air conditioners contain refrigerants, 

which under federal law must be removed 

prior to product disposal. If you are getting 

rid of an old product with refrigerants, check 

with the company handling disposal about 

what to do.

„

If the receptacle does not match the plug, 

the receptacle must be changed out by a 

qualified electrician.

„

These R410A air conditioning systems 

require contractors and technicians to  

use tools, equipment and safety standards 

approved for use with this refrigerant.  

DO NOT use equipment certified for  

R22 refrigerant only.

SAFETY PRECAUTIONS

Do not, under any circumstances, cut or remove 

the third (ground) prong from the power cord.  

For personal safety, this appliance must be 

properly grounded.

  DO NOT use an adapter plug with this 

appliance.

The power cord of this appliance is equipped 

with a 3-prong (grounding) plug which mates 

with a standard 3-prong (grounding) wall outlet 

to minimize the possibility of electric shock 

hazard from this appliance.
Power cord includes a current interrupter device. 

A test and reset button is provided on the plug 

case. The device should be tested on a periodic 

basis by first pressing the 

TEST

 button and 

then the 

RESET

 button while plugged into the 

outlet. If the 

TEST

 button does not trip or if the 

RESET

 button will not stay engaged, discontinue 

use of the air conditioner and contact a qualified 

service technician.

Have the wall outlet and circuit checked by  

a qualified electrician to make sure the outlet  

is properly grounded.
Where a 2-prong wall outlet is encountered,  

it is your personal responsibility and obligation to 

have it replaced with a properly grounded  

3-prong wall outlet.
The air conditioner should always be plugged 

into its own individual electrical outlet which has 

a voltage rating that matches the rating plate.
This provides the best performance and also 

prevents overloading house wiring circuits which 

could cause a fire hazard from overheated wires.
See the Installation Instructions,

 Electrical 

Requirements

 section for specific electrical 

connection requirements. 

HOW TO CONNECT ELECTRICITY

Summary of Contents for AHV05LR

Page 1: ...mer Support Warranty for Customers in the U S A 13 Consumer Support 14 49 7708 10 12 GE AHV05 Owner s Manual and Installation Instructions Write the model and serial numbers here Model _______________...

Page 2: ...ctrician These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for...

Page 3: ...OLLOW THIS SAFETY INFORMATION CAREFULLY SAVE THESE INSTRUCTIONS RISK OF FIRE Could cause serious injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protecto...

Page 4: ...tes before switching back to a cool setting Cooling Descriptions RU 1RUPDO RROLQJ Select High Cool or Low Cool For Maximum Cooling 6HOHFW High Cool with the FAN SPEED set to HI For Quieter and Nightti...

Page 5: ...or abrasives Grille and Case Air Filter The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary To remove Open the inlet grille by pulli...

Page 6: ...y to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt AC protected with a time delay fuse or circuit breaker These models should be installed on their own...

Page 7: ...nstallation Instructions Type A screws 3 Side curtains 2 Foam seal Top channel Air conditioner Window lock bracket 3 PARTS INCLUDED Appearance may vary Side curtains frames 2 Type B screws 7 Bottom se...

Page 8: ...windows t The air conditioner can be installed without the side curtain if needed to fit in a narrow window See the window opening dimensions t All supporting parts must be secured to firm wood mason...

Page 9: ...cure the side panels in place Type B screws About 1 4 Bottom guide Window frame Top channel Window lock bracket 5 A PREPARING THE WINDOW FOR INSTALLATION Measure the width of the window opening and ma...

Page 10: ...he window to prevent air and insects from getting into the room NOTE If the gasket supplied does not fit your window obtain appropriate material locally to provide a proper installation seal A CAUTION...

Page 11: ...ord plug device is tripped tIf the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Air conditioner does Airflow is restricted tMake...

Page 12: ...NOTES 12...

Page 13: ...is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caus...

Page 14: ...1 Factory Lane Moncton N B E1C 9M3 Parts and Accessories In the U S A GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes...

Page 15: ...al Cliente Garant a para Clientes en EE UU 13 Soporte al Cliente 14 49 7708 10 12 GE AHV05 Manual del Propietario e Instrucciones de Instalaci n Escriba los n meros de modelo y de serie aqu N de Model...

Page 16: ...cos utilicen herramientas equipamiento y est ndares de seguridad aprobados para su uso con este refrigerante NO use equipamiento certificado s lo para refrigerante R22 PRECAUCIONES DE SEGURIDAD Nunca...

Page 17: ...DOSAMENTE GUARDE ESTAS INSTRUCCIONES RIESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos de...

Page 18: ...XQ 1LYHO GH UtR 1RUPDO Seleccione High Cool Fr o Alto o Low Cool Fr o Bajo Para un Nivel de Fr o M ximo 6HOHFFLRQH High Cool Fr o Alto con la configuraci n FAN SPEED Velocidad del Ventilador en HI Alt...

Page 19: ...de Aire El filtro de aire que se encuentra detr s de la rejilla frontal se debe revisar y limpiar por lo menos cada 30 d as o con una frecuencia mayor si fuera necesario Para retirar Abra la rejilla d...

Page 20: ...ables es su responsabilidad y obligaci n reemplazarlo por un tomacorriente de pared de 3 cables correctamente conectado a tierra Algunos modelos requieren CA de 230 208 voltios protegido con un fusibl...

Page 21: ...s Tipo A 3 Cortinas laterales 2 Sello de gomaespuma Canal superior Acondicionador de aire Soporte de cierre de la ventana 3 PARTES INCLUIDAS La apariencia puede variar Marcos de las cortinas laterales...

Page 22: ...superior del marco de la contraventana o el marco de vinilo Adjunte de forma segura con clavos o tornillos provistos por el instalador Instrucciones de Instalaci n REQUISITOS PARA VENTANA t Estas inst...

Page 23: ...ente 1 4 Gu a inferior Marco de la ventana Canal superior Soporte de blo queo de la ventana 5 A PREPARACI N PARA LA INSTALACI N DE LA VENTANA Mida el ancho de la abertura de la ventana y marque la l n...

Page 24: ...rio y la ventana para evitar el ingreso de aire e insectos a la habitaci n NOTA Si la junta provista no se ajusta a su ventana obtenga el material apropiado en forma local para contar con un sellado c...

Page 25: ...conectado interrumpa el uso del acondicionador de aire y comun quese con un t cnico calificado del servicio El acondicionador de aire El flujo de aire est obstruido tAseg rese que no haya cortinas per...

Page 26: ...NOTAS 12...

Page 27: ...cubierto Esta garant a se extiende al comprador original y cualquier comprador posterior de productos comprados para uso residencial dentro de Estados Unidos Si el producto est situado en un rea que n...

Page 28: ...personas con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios GEAppliances com Aquellos individuos con la calificaci n necesaria para reparar sus propios electro...

Reviews: