background image

 

Troubleshooting Tips.

 

Normal Operating Sounds

„

You may hear a pinging noise caused by 
water being picked up and thrown against the 
condenser on rainy days or when the humidity  
is high. This design feature helps remove 
moisture and improve efficiency.

„

You may hear the thermostat click when the 
compressor cycles on and off.

„

Water will collect in the base pan during
high humidity or on rainy days. The water 
may overflow and drip from the outdoor side 
of the unit.

„

The fan may run even when the compressor 
does not.

Problem 

Possible Causes 

What To Do

Air conditioner

 

The air conditioner

 

t

Make sure the air conditioner plug is pushed

does not start

 

is unplugged.

 

  completely into the outlet.

 

The fuse is blown/circuit

 

t

 Check the house fuse/circuit breaker box and replace

 

breaker is tripped.

 

  the fuse or reset the breaker.

 

Power failure.

 

t

The unit will automatically restart in the settings last 

 

 

  used after the power is restored.

 

 

t

There is a protective time delay (approximately   

 

 

 

  3 minutes) to prevent tripping of the compressor  

 

 

 

  overload. For this reason, the unit may not start  

 

 

 

  normal cooling for 3 minutes after it is turned    

 

  

 

back 

on.

 

The current interrupter

 

t

Press the 

RESET

 button located on the power cord plug.

 

device is tripped.

 

t

If the 

RESET

 button will not stay engaged, discontinue 

 

 

  use of the air conditioner and contact a qualified  

  

 

service 

technician.

Air conditioner does

 

Airflow is restricted.

 

t

 Make sure there are no curtains, blinds or furniture

not cool as it should

 

 

  blocking the front of the air conditioner.

 

The temp control may

‡7XUQWKHWHPSHUDWXUHNQREWRDKLJKHUQXPEHU

 

not be set correctly.

 

 

 

 

 

 

 

 

The air filter is dirty.

 

t

 Clean the filter at least every 30 days.

 

 

  See the Care and Cleaning section.

 

The room may have been hot.

 

t

 When the air conditioner is first turned on, you need 

 

 

  to allow time for the room to cool down.

 

Cold air is escaping.

 

t

 Check for open furnace registers and cold air returns.

 

Cooling coils have iced up.

 

t

See “Air conditioner freezing up” below.

Air conditioner

 

Ice blocks the air flow

 

t

 On models with control knobs, set the mode control at  

 

freezing up

 

and stops the air conditioner

 

  High Fan or High Cool with the Temp at 1 or 2.

 

from cooling the room.

 

Water drips outside

 

Hot, humid weather. 

 

t

 This is normal.

Water drips indoors

 

The air conditioner is not

 

t

 For proper water disposal, make sure the air conditioner

 

tilted to the outside.

 

  slants slightly from the case front to the rear.

Water collects in 

 

Moisture removed from air 

 

t

 This is normal for a short period in areas with little

base pan

 

and drains into base pan.

 

  humidity; normal for a longer period in very humid areas.

11

Summary of Contents for AHV05LR

Page 1: ...mer Support Warranty for Customers in the U S A 13 Consumer Support 14 49 7708 10 12 GE AHV05 Owner s Manual and Installation Instructions Write the model and serial numbers here Model _______________...

Page 2: ...ctrician These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for...

Page 3: ...OLLOW THIS SAFETY INFORMATION CAREFULLY SAVE THESE INSTRUCTIONS RISK OF FIRE Could cause serious injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protecto...

Page 4: ...tes before switching back to a cool setting Cooling Descriptions RU 1RUPDO RROLQJ Select High Cool or Low Cool For Maximum Cooling 6HOHFW High Cool with the FAN SPEED set to HI For Quieter and Nightti...

Page 5: ...or abrasives Grille and Case Air Filter The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary To remove Open the inlet grille by pulli...

Page 6: ...y to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt AC protected with a time delay fuse or circuit breaker These models should be installed on their own...

Page 7: ...nstallation Instructions Type A screws 3 Side curtains 2 Foam seal Top channel Air conditioner Window lock bracket 3 PARTS INCLUDED Appearance may vary Side curtains frames 2 Type B screws 7 Bottom se...

Page 8: ...windows t The air conditioner can be installed without the side curtain if needed to fit in a narrow window See the window opening dimensions t All supporting parts must be secured to firm wood mason...

Page 9: ...cure the side panels in place Type B screws About 1 4 Bottom guide Window frame Top channel Window lock bracket 5 A PREPARING THE WINDOW FOR INSTALLATION Measure the width of the window opening and ma...

Page 10: ...he window to prevent air and insects from getting into the room NOTE If the gasket supplied does not fit your window obtain appropriate material locally to provide a proper installation seal A CAUTION...

Page 11: ...ord plug device is tripped tIf the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Air conditioner does Airflow is restricted tMake...

Page 12: ...NOTES 12...

Page 13: ...is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caus...

Page 14: ...1 Factory Lane Moncton N B E1C 9M3 Parts and Accessories In the U S A GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes...

Page 15: ...al Cliente Garant a para Clientes en EE UU 13 Soporte al Cliente 14 49 7708 10 12 GE AHV05 Manual del Propietario e Instrucciones de Instalaci n Escriba los n meros de modelo y de serie aqu N de Model...

Page 16: ...cos utilicen herramientas equipamiento y est ndares de seguridad aprobados para su uso con este refrigerante NO use equipamiento certificado s lo para refrigerante R22 PRECAUCIONES DE SEGURIDAD Nunca...

Page 17: ...DOSAMENTE GUARDE ESTAS INSTRUCCIONES RIESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos de...

Page 18: ...XQ 1LYHO GH UtR 1RUPDO Seleccione High Cool Fr o Alto o Low Cool Fr o Bajo Para un Nivel de Fr o M ximo 6HOHFFLRQH High Cool Fr o Alto con la configuraci n FAN SPEED Velocidad del Ventilador en HI Alt...

Page 19: ...de Aire El filtro de aire que se encuentra detr s de la rejilla frontal se debe revisar y limpiar por lo menos cada 30 d as o con una frecuencia mayor si fuera necesario Para retirar Abra la rejilla d...

Page 20: ...ables es su responsabilidad y obligaci n reemplazarlo por un tomacorriente de pared de 3 cables correctamente conectado a tierra Algunos modelos requieren CA de 230 208 voltios protegido con un fusibl...

Page 21: ...s Tipo A 3 Cortinas laterales 2 Sello de gomaespuma Canal superior Acondicionador de aire Soporte de cierre de la ventana 3 PARTES INCLUIDAS La apariencia puede variar Marcos de las cortinas laterales...

Page 22: ...superior del marco de la contraventana o el marco de vinilo Adjunte de forma segura con clavos o tornillos provistos por el instalador Instrucciones de Instalaci n REQUISITOS PARA VENTANA t Estas inst...

Page 23: ...ente 1 4 Gu a inferior Marco de la ventana Canal superior Soporte de blo queo de la ventana 5 A PREPARACI N PARA LA INSTALACI N DE LA VENTANA Mida el ancho de la abertura de la ventana y marque la l n...

Page 24: ...rio y la ventana para evitar el ingreso de aire e insectos a la habitaci n NOTA Si la junta provista no se ajusta a su ventana obtenga el material apropiado en forma local para contar con un sellado c...

Page 25: ...conectado interrumpa el uso del acondicionador de aire y comun quese con un t cnico calificado del servicio El acondicionador de aire El flujo de aire est obstruido tAseg rese que no haya cortinas per...

Page 26: ...NOTAS 12...

Page 27: ...cubierto Esta garant a se extiende al comprador original y cualquier comprador posterior de productos comprados para uso residencial dentro de Estados Unidos Si el producto est situado en un rea que n...

Page 28: ...personas con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios GEAppliances com Aquellos individuos con la calificaci n necesaria para reparar sus propios electro...

Reviews: