BEFORE YOU BEGIN

Read these instructions completely  
and carefully.

t

 

 

IMPORTANT

 

 Save these instructions 

for local inspector’s use.

t

 

 

IMPORTANT

 

 Observe all governing 

codes and ordinances.

t

 

Note to Installer

 – 

Be sure to leave these 

instructions with the Consumer.

t

 Note to Consumer

 – 

Keep these instructions for 

future reference.

t

 

Skill level 

– 

Installation of this appliance 

requires basic mechanical skills.

t

Completion time

 – 

 

Approximately 1 hour

t

 We recommend that two people install 

this product.

t

 Proper installation is the responsibility 

of the installer.

t

 Product failure due to improper installation is not 

covered under the Warranty.

t

 You MUST use all supplied parts and use proper 

installation procedures as described in these 

instructions when installing this air conditioner.

 Installation  

Air Conditioner 

 

  

 

Instructions

  

  

  Some models require a 115/120-volt AC,

60-Hz grounded outlet protected with a 

15-amp time-delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the 

possibility of electric shock hazard. If the wall outlet you 

plan to use is only a 2-prong outlet,  

it is your responsibility to have it replaced with  

a properly grounded 3-prong wall outlet.

  Some models require 230/208-volt AC, 

protected with a time-delay fuse or circuit 

breaker. These models should be installed on 

their own single branch circuit for best 

performance and to prevent overloading 

house or apartment wiring circuits, which 

could cause a possible fire hazard from 

overheating wires.

ELECTRICAL REQUIREMENTS

CAUTION:

Do not, under any circumstances, cut or remove the 
third (ground) prong from the power cord.
Do not change the plug on the power cord of this air 
conditioner.
Aluminum house wiring may present special 
problems—consult a qualified electrician.

  Power cord includes a current interrupter  

device. A test and reset button is provided on the 

plug case. The device should be tested on a periodic 

basis by first pressing the 

TEST

 button and then the 

RESET

 button while plugged into the outlet. If the 

TEST

 button does not trip or if the 

RESET

 button will not 

stay engaged, discontinue use of the air conditioner 

and contact a qualified service technician.

Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com
In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca

6

TOOLS YOU WILL NEED

Phillips head screwdriver

Ruler or tape measure

Pencil

Level

Scissors or knife

Drill and 1/8” drill bit

Summary of Contents for AHV05LR

Page 1: ...mer Support Warranty for Customers in the U S A 13 Consumer Support 14 49 7708 10 12 GE AHV05 Owner s Manual and Installation Instructions Write the model and serial numbers here Model _______________...

Page 2: ...ctrician These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for...

Page 3: ...OLLOW THIS SAFETY INFORMATION CAREFULLY SAVE THESE INSTRUCTIONS RISK OF FIRE Could cause serious injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protecto...

Page 4: ...tes before switching back to a cool setting Cooling Descriptions RU 1RUPDO RROLQJ Select High Cool or Low Cool For Maximum Cooling 6HOHFW High Cool with the FAN SPEED set to HI For Quieter and Nightti...

Page 5: ...or abrasives Grille and Case Air Filter The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary To remove Open the inlet grille by pulli...

Page 6: ...y to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt AC protected with a time delay fuse or circuit breaker These models should be installed on their own...

Page 7: ...nstallation Instructions Type A screws 3 Side curtains 2 Foam seal Top channel Air conditioner Window lock bracket 3 PARTS INCLUDED Appearance may vary Side curtains frames 2 Type B screws 7 Bottom se...

Page 8: ...windows t The air conditioner can be installed without the side curtain if needed to fit in a narrow window See the window opening dimensions t All supporting parts must be secured to firm wood mason...

Page 9: ...cure the side panels in place Type B screws About 1 4 Bottom guide Window frame Top channel Window lock bracket 5 A PREPARING THE WINDOW FOR INSTALLATION Measure the width of the window opening and ma...

Page 10: ...he window to prevent air and insects from getting into the room NOTE If the gasket supplied does not fit your window obtain appropriate material locally to provide a proper installation seal A CAUTION...

Page 11: ...ord plug device is tripped tIf the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Air conditioner does Airflow is restricted tMake...

Page 12: ...NOTES 12...

Page 13: ...is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caus...

Page 14: ...1 Factory Lane Moncton N B E1C 9M3 Parts and Accessories In the U S A GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes...

Page 15: ...al Cliente Garant a para Clientes en EE UU 13 Soporte al Cliente 14 49 7708 10 12 GE AHV05 Manual del Propietario e Instrucciones de Instalaci n Escriba los n meros de modelo y de serie aqu N de Model...

Page 16: ...cos utilicen herramientas equipamiento y est ndares de seguridad aprobados para su uso con este refrigerante NO use equipamiento certificado s lo para refrigerante R22 PRECAUCIONES DE SEGURIDAD Nunca...

Page 17: ...DOSAMENTE GUARDE ESTAS INSTRUCCIONES RIESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos de...

Page 18: ...XQ 1LYHO GH UtR 1RUPDO Seleccione High Cool Fr o Alto o Low Cool Fr o Bajo Para un Nivel de Fr o M ximo 6HOHFFLRQH High Cool Fr o Alto con la configuraci n FAN SPEED Velocidad del Ventilador en HI Alt...

Page 19: ...de Aire El filtro de aire que se encuentra detr s de la rejilla frontal se debe revisar y limpiar por lo menos cada 30 d as o con una frecuencia mayor si fuera necesario Para retirar Abra la rejilla d...

Page 20: ...ables es su responsabilidad y obligaci n reemplazarlo por un tomacorriente de pared de 3 cables correctamente conectado a tierra Algunos modelos requieren CA de 230 208 voltios protegido con un fusibl...

Page 21: ...s Tipo A 3 Cortinas laterales 2 Sello de gomaespuma Canal superior Acondicionador de aire Soporte de cierre de la ventana 3 PARTES INCLUIDAS La apariencia puede variar Marcos de las cortinas laterales...

Page 22: ...superior del marco de la contraventana o el marco de vinilo Adjunte de forma segura con clavos o tornillos provistos por el instalador Instrucciones de Instalaci n REQUISITOS PARA VENTANA t Estas inst...

Page 23: ...ente 1 4 Gu a inferior Marco de la ventana Canal superior Soporte de blo queo de la ventana 5 A PREPARACI N PARA LA INSTALACI N DE LA VENTANA Mida el ancho de la abertura de la ventana y marque la l n...

Page 24: ...rio y la ventana para evitar el ingreso de aire e insectos a la habitaci n NOTA Si la junta provista no se ajusta a su ventana obtenga el material apropiado en forma local para contar con un sellado c...

Page 25: ...conectado interrumpa el uso del acondicionador de aire y comun quese con un t cnico calificado del servicio El acondicionador de aire El flujo de aire est obstruido tAseg rese que no haya cortinas per...

Page 26: ...NOTAS 12...

Page 27: ...cubierto Esta garant a se extiende al comprador original y cualquier comprador posterior de productos comprados para uso residencial dentro de Estados Unidos Si el producto est situado en un rea que n...

Page 28: ...personas con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios GEAppliances com Aquellos individuos con la calificaci n necesaria para reparar sus propios electro...

Reviews: