About the controls on the air conditioner.

 

Cool Mode

Use the Cool mode at Low, Med, High or Auto Fan 

Speed for cooling. Use the Temperature Increase 

Ÿ

 

/ Decrease 

ź

 pads to set the desired temperature 

between 64°F and 86°F in 1°F increments. 
An electronic thermostat is used to maintain the room 

temperature. The compressor will cycle on and off 

to keep the room at the set level of comfort. Set the 

thermostat at a lower number and the indoor air will 

become cooler. Set the thermostat at a higher number 

and the indoor air will become warmer.
NOTE: If the air conditioner is off and is then turned on  

while set to a Cool setting or if turned from a fan setting 

to a Cool setting, it may take approximately 3 minutes 

for the compressor to start and cooling to begin.

Cooling Descriptions

For Normal Cooling

³6HOHFWWKH

Cool mode and  

High or Med fan with a middle set temperature.
For Maximum Cooling

³6HOHFWWKH

Cool mode  

and High fan with a lower set temperature.
For Quieter and Nighttime Cooling

³6HOHFWWKH

 

Cool mode and Low fan with a middle set 

temperature.

Fan Only Mode

Use the Fan Only Mode at Low, Med or High fan 

speed to provide air circulation and filtering without 

cooling. Since fan-only settings do not provide 

cooling, a Set temperature cannot be entered. The 

room temperature will appear  

in the display.

NOTE: Auto Fan Speed cannot be used when in the  

Fan Only Mode. 

Energy Saver Mode

Controls the fan.
ON

³7KHIDQZLOOF\FOHRQDQGRIIZLWKWKH

compressor. This results in wider variations of room 
temperature and humidity. Normally used when the 
room is unoccupied. NOTE: The fan may continue to 
run for a short time after the compressor cycles off.

OFF

³7KHIDQUXQVDOOWKHWLPHZKLOHWKHFRPSUHVVRU

cycles on and off.

Set to Auto fan speed for the fan speed to 
automatically set to the speed needed to provide 
optimum comfort settings with the set temperature.   
If the room needs more cooling, the fan speed  
will automatically increase. If the room needs less 
cooling, the fan speed will automatically decrease. 

NOTE: Auto Fan Speed cannot be used when in the  

Fan Only Mode. 

Auto Fan Speed

Do Not Operate in Freezing Outdoor 

Conditions

This cool-only air conditioner was not designed for 

freezing outdoor conditions. It must not be used in 

freezing outdoor conditions.

In the case of a power outage or interruption, the 
unit will automatically restart in the settings last 
used after the power is restored. If the Delay 1–24hr 

feature was set, it will resume countdown. You may 
need to set a new time if desired.

Power Outage Recovery Feature

„

To ensure proper operation, aim the remote 
control at the signal receiver on the air 
conditioner.

„

 

Make sure nothing is between the air conditioner 
and the remote control that could block the 
signal.

„

 

The remote control signal has a range of  
up to 20 feet.

„

 

Make sure batteries are fresh and installed 
correctly as indicated on the remote control.

„

 

Remote contains a magnet allowing it to attach 
to metal surfaces.

Remote Control

Summary of Contents for AEZ05

Page 1: ...Warranty 14 49 7654 2 10 13 GE AET05 AEW05 AEY05 AEZ05 AEW06 AEZ06 AEW08 AEZ08 Owner s Manual and Installation Instructions Write the model and serial numbers here Model _________________________ Seri...

Page 2: ...trician These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for R...

Page 3: ...ENSION CORDS RISK OF FIRE Could cause serious injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protectors or multi outlet adaptors with this Window Air Co...

Page 4: ...set Press the Delay 1 24hr pad on the unit or the Delay pad on the remote control Each touch of the Increase Decrease pads on the unit or the Increase Decrease pads on the remote control will set the...

Page 5: ...Select High Cool or Low Cool with the TEMPERATURE control at midpoint For Maximum Cooling 6HOHFW High Cool with the TEMPERATURE control at the highest number available on your knob For Quieter and Nig...

Page 6: ...er Mode Controls the fan ON 7KH IDQ ZLOO F FOH RQ DQG RII ZLWK WKH compressor This results in wider variations of room temperature and humidity Normally used when the room is unoccupied NOTE The fan m...

Page 7: ...oils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally cleaned GEAppliances com Turn the air conditioner off and r...

Page 8: ...t replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt AC protected with a time delay fuse or circuit breaker These models should be installed on their own single bra...

Page 9: ...Right accordion panel Type A 4 Type B 6 Foam top window gasket Left accordion panel Window sash seal Top mounting rail Air conditioner Window locking bracket 1 PARTS INCLUDED Appearance may vary Top m...

Page 10: ...e the window frame THICKNESS To determine the thickness place a piece of wood on the sill to make it 1 2s higher than the top of the storm window frame or the vinyl frame Attach securely with nails or...

Page 11: ...lant to the outside Extend the left and right accordion panels to the vertical window sashes and attach through the holes in the panels with 5 Type B screws as appropriate 6 A B PREPARE THE WINDOW Cut...

Page 12: ...e sure there are no curtains blinds or furniture not cool as it should blocking the front of the air conditioner The temp control may On models with touch pads In the Cool mode press the not be set co...

Page 13: ...ot Covered Properly pack your unit We recommend using the original carton and packing materials Return the product to the retail location where it was purchased Include in the package a copy of the sa...

Page 14: ...ucciones de instalaci n 21 24 Solucionar problemas 25 Sonidos de operaci n normales 25 Servicio al consumidor Garant a 26 Apoyo al consumidor 27 Escriba los n meros de modelo y serie aqu de Modelo____...

Page 15: ...TENCIA Por su seguridad se debe seguir la informaci n en este manual para minimizar el riesgo de incendios descargas el ctricas o lesiones personales Use este electrodom stico solamente para el prop s...

Page 16: ...IESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos de tensi n ni adaptadores para m ltiples...

Page 17: ...dentro de 1 a 24 horas en el modo y configuraci n de ventilador anterior HOD 2 3 2 5HWDUGR Cuando el acondicionador de aire est encendido puede ajustarse para que se apague autom ticamente dentro de...

Page 18: ...l 6HOHFFLRQH High Cool Fr o Alto o Low Cool Fr o Bajo con el control de TEMPERATURA en el punto intermedio Para una Refrigeraci n M xima 6HOHFFLRQH High Cool Fr o Alto con el control de TEMPERATURA en...

Page 19: ...modo Fan only Solo ventilador a velocidad Low Baja Med Media o High Alta para proporcionar circulaci n de aire y filtraci n sin enfriamiento Debido a que los niveles de ventilador nicamente no proporc...

Page 20: ...controles en el acondicionador de aire Apague el acondicionador de aire y retire el enchufe del tomacorriente de la pared antes de limpiar Para limpiar use agua y un detergente suave No use cloro o m...

Page 21: ...e acondicionador de aire Los cables caseros de aluminio podr an presentar problemas especiales Consulte a un t cnico electricista calificado ANTES DE INICIAR Lea estas instrucciones completa y cuidado...

Page 22: ...a Panel de acorde n derecho Tipo A 4 Tipo B 6 Junta de espuma superior de la ventana Panel de acorde n izquierdo Sello de la banda de la ventana Riel de montaje superior Acondicionador de aire Soporte...

Page 23: ...r de aire se incline hacia el exterior y evitar que drene apropiadamente Parasolucionareste problema adhiera un pedazo de madera a el umbral PEDAZOS DE MADERA ANCHO 2s LONGITUD Lo suficientemente larg...

Page 24: ...entana Rellene la espuma entre el vidrio y la ventana para evitar que aire e insectos se introduzcan en la habitaci n NOTA Si la junta provista no es adecuada para su ventana obtenga el material aprop...

Page 25: ...no enfr a como deber a mueble bloqueando el frente del acondicionador de aire El control de temperatura no En los modelos con teclado En el modo Cool Fr o presione la tecla est ajustado apropiadamente...

Page 26: ...enimiento razonable y necesario Reemplazo de fusibles de la casa o reajuste del sistema de circuitos Fallo debido a la corrosi n en modelos que no est n protegidos contra la corrosi n Da o al producto...

Page 27: ...con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios GEAppliances com Aquellos individuos con la calificaci n necesaria para reparar sus propios electrodom stico...

Page 28: ...ite 310 1 Factory Lane Moncton N B E1C 9M3 Parts and Accessories In the U S A GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to thei...

Reviews: