Troubleshooting Tips. 

GEAppliances.com

Normal Operating Sounds

„

You may hear a pinging noise caused by 
water being picked up and thrown against the 
condenser on rainy days or when the humidity  
is high. This design feature helps remove 
moisture and improve efficiency.

„

You may hear the thermostat click when the 
compressor cycles on and off.

„

Water will collect in the base pan during 
high humidity or on rainy days. The water 
may overflow and drip from the outdoor side 
of the unit.

„

The fan may run even when the compressor  
does not.

Problem 

Possible Causes 

What To Do

Air conditioner 

The air conditioner 

‡Make sure the air conditioner plug is pushed 

does not start 

is unplugged. 

  completely into the outlet.

 

The fuse is blown/circuit 

‡ Check the house fuse/circuit breaker box and replace 

 

breaker is tripped. 

  the fuse or reset the breaker.

 

Power failure. 

‡ The unit will automatically restart in the settings last  

 

 

  used after the power is restored.

 

 

‡ There is a protective time delay (approximately   

 

 

 

  3 minutes) to prevent tripping of the compressor  

 

 

 

  overload. For this reason, the unit may not start  

 

 

 

  normal cooling for 3 minutes after it is turned    

 

  

 

back 

on.

 

The current interrupter 

‡ Press the RESET button located on the power cord plug.

 

device is tripped. 

‡ If  the  RESET button will not stay engaged, discontinue  

 

 

  use of the air conditioner and contact a qualified  

  

 

service 

technician.

Air conditioner does 

Airflow is restricted. 

‡ Make sure there are no curtains, blinds or furniture 

not cool as it should 

 

  blocking the front of the air conditioner.

 

The temp control may 

‡ On models with touch pads: In the Cool mode, press the 

 

not be set correctly.  

Decrease 

ź

 pad.

‡2QPRGHOVZLWKFRQWURONQREVWXUQWKHWHPSHUDWXUH

 

 

 

  knob to a higher number.

 

The air filter is dirty. 

‡ Clean the filter at least every 30 days. 

  

 

See 

the 

Care and Cleaning section.

 

The room may have been hot. 

‡ When the air conditioner is first turned on, you need  

 

 

  to allow time for the room to cool down.

 

Cold air is escaping. 

‡ Check for open furnace registers and cold air returns.

 

Cooling coils have iced up. 

‡ See  “Air conditioner freezing up” below.

Air conditioner 

Ice blocks the air flow 

‡ On models with control knobs, set the mode control at  

 

freezing up 

and stops the air conditioner 

 High Fan or High Cool with the Temp at or 2.

 

from cooling the room.

‡2QPRGHOVZLWKWRXFKSDGVVHWWKHFRQWUROVDW

 High Fan    

  

 

or 

High Cool and set the thermostat to a higher    

 

  

 

temperature.

The remote control   

The batteries are inserted 

‡ Check the position of the batteries. They should be  

is not working 

incorrectly. 

  inserted in the opposite (+) and (–) direction.

 

The batteries may be dead. 

‡Replace the batteries.

Water drips outside 

Hot, humid weather.  

‡ This is normal.

Water drips indoors 

The air conditioner is not 

‡ For proper water disposal, make sure the air conditioner 

 

tilted to the outside. 

  slants slightly from the case front to the rear.

Water collects in  

Moisture removed from air  

‡ This is normal for a short period in areas with little 

base pan 

and drains into base pan. 

  humidity; normal for a longer period in very humid areas.

Summary of Contents for AEZ05

Page 1: ...Warranty 14 49 7654 2 10 13 GE AET05 AEW05 AEY05 AEZ05 AEW06 AEZ06 AEW08 AEZ08 Owner s Manual and Installation Instructions Write the model and serial numbers here Model _________________________ Seri...

Page 2: ...trician These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for R...

Page 3: ...ENSION CORDS RISK OF FIRE Could cause serious injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protectors or multi outlet adaptors with this Window Air Co...

Page 4: ...set Press the Delay 1 24hr pad on the unit or the Delay pad on the remote control Each touch of the Increase Decrease pads on the unit or the Increase Decrease pads on the remote control will set the...

Page 5: ...Select High Cool or Low Cool with the TEMPERATURE control at midpoint For Maximum Cooling 6HOHFW High Cool with the TEMPERATURE control at the highest number available on your knob For Quieter and Nig...

Page 6: ...er Mode Controls the fan ON 7KH IDQ ZLOO F FOH RQ DQG RII ZLWK WKH compressor This results in wider variations of room temperature and humidity Normally used when the room is unoccupied NOTE The fan m...

Page 7: ...oils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally cleaned GEAppliances com Turn the air conditioner off and r...

Page 8: ...t replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt AC protected with a time delay fuse or circuit breaker These models should be installed on their own single bra...

Page 9: ...Right accordion panel Type A 4 Type B 6 Foam top window gasket Left accordion panel Window sash seal Top mounting rail Air conditioner Window locking bracket 1 PARTS INCLUDED Appearance may vary Top m...

Page 10: ...e the window frame THICKNESS To determine the thickness place a piece of wood on the sill to make it 1 2s higher than the top of the storm window frame or the vinyl frame Attach securely with nails or...

Page 11: ...lant to the outside Extend the left and right accordion panels to the vertical window sashes and attach through the holes in the panels with 5 Type B screws as appropriate 6 A B PREPARE THE WINDOW Cut...

Page 12: ...e sure there are no curtains blinds or furniture not cool as it should blocking the front of the air conditioner The temp control may On models with touch pads In the Cool mode press the not be set co...

Page 13: ...ot Covered Properly pack your unit We recommend using the original carton and packing materials Return the product to the retail location where it was purchased Include in the package a copy of the sa...

Page 14: ...ucciones de instalaci n 21 24 Solucionar problemas 25 Sonidos de operaci n normales 25 Servicio al consumidor Garant a 26 Apoyo al consumidor 27 Escriba los n meros de modelo y serie aqu de Modelo____...

Page 15: ...TENCIA Por su seguridad se debe seguir la informaci n en este manual para minimizar el riesgo de incendios descargas el ctricas o lesiones personales Use este electrodom stico solamente para el prop s...

Page 16: ...IESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos de tensi n ni adaptadores para m ltiples...

Page 17: ...dentro de 1 a 24 horas en el modo y configuraci n de ventilador anterior HOD 2 3 2 5HWDUGR Cuando el acondicionador de aire est encendido puede ajustarse para que se apague autom ticamente dentro de...

Page 18: ...l 6HOHFFLRQH High Cool Fr o Alto o Low Cool Fr o Bajo con el control de TEMPERATURA en el punto intermedio Para una Refrigeraci n M xima 6HOHFFLRQH High Cool Fr o Alto con el control de TEMPERATURA en...

Page 19: ...modo Fan only Solo ventilador a velocidad Low Baja Med Media o High Alta para proporcionar circulaci n de aire y filtraci n sin enfriamiento Debido a que los niveles de ventilador nicamente no proporc...

Page 20: ...controles en el acondicionador de aire Apague el acondicionador de aire y retire el enchufe del tomacorriente de la pared antes de limpiar Para limpiar use agua y un detergente suave No use cloro o m...

Page 21: ...e acondicionador de aire Los cables caseros de aluminio podr an presentar problemas especiales Consulte a un t cnico electricista calificado ANTES DE INICIAR Lea estas instrucciones completa y cuidado...

Page 22: ...a Panel de acorde n derecho Tipo A 4 Tipo B 6 Junta de espuma superior de la ventana Panel de acorde n izquierdo Sello de la banda de la ventana Riel de montaje superior Acondicionador de aire Soporte...

Page 23: ...r de aire se incline hacia el exterior y evitar que drene apropiadamente Parasolucionareste problema adhiera un pedazo de madera a el umbral PEDAZOS DE MADERA ANCHO 2s LONGITUD Lo suficientemente larg...

Page 24: ...entana Rellene la espuma entre el vidrio y la ventana para evitar que aire e insectos se introduzcan en la habitaci n NOTA Si la junta provista no es adecuada para su ventana obtenga el material aprop...

Page 25: ...no enfr a como deber a mueble bloqueando el frente del acondicionador de aire El control de temperatura no En los modelos con teclado En el modo Cool Fr o presione la tecla est ajustado apropiadamente...

Page 26: ...enimiento razonable y necesario Reemplazo de fusibles de la casa o reajuste del sistema de circuitos Fallo debido a la corrosi n en modelos que no est n protegidos contra la corrosi n Da o al producto...

Page 27: ...con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios GEAppliances com Aquellos individuos con la calificaci n necesaria para reparar sus propios electrodom stico...

Page 28: ...ite 310 1 Factory Lane Moncton N B E1C 9M3 Parts and Accessories In the U S A GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to thei...

Reviews: