16. Lift up the Air Tunnel Inlet, then remove wiring
from the 2 retainers.
17. Push wiring through the entry hole, then remove
the Air Tunnel Inlet.
Retainer
Retainer
Air Tunnel Cover
The Air Tunnel Cover must be removed when
replacing the Upper Heater Assembly, TCO, and
stirrer motor.
To remove the Air Tunnel Cover:
1. Remove the Outer Cover. (See
Outer Cover
.)
2. Remove the Ventilation Motor. (See
Ventilation
Motor
.)
3. Compress the 2 pins holding the 2 wire retainers
to the Air Tunnel Cover.
4. Remove the 8 Phillips-head screws that attach
the Air Tunnel Cover to the top of the oven.
Pin
Pin
5. Lift the cover and disconnect the light bulb wire
harness.
Harness
Air Tunnel Outlet
The Air Tunnel Outlet must be removed to access
the Oven TCO and the Upper Heater Assembly and
TCO.
To remove the Air Tunnel Outlet:
1. Remove the Humidity Sensor. (See
Humidity
Sensor
.)
2. Remove the 3 Phillips-head screws that attach
the Air Tunnel Outlet to the oven.
(