– 16 –
Installation
Advanced Planning
The product should not be installed over any
cooktop or range with a combined BTU greater than
60000 BTU.
This oven is for installation over ranges up to 36
inches wide.
The space between the cabinets must be 30 inches
wide and free of obstructions. If the space between
the cabinets is greater than 30 inches, a
fi
ller panel
kit may be used to
fi
ll in the gap between the oven
and the cabinets. Filler panel kits available from GE
are: White - JX52WH, and Black - JX52BL. These
fi
ller
kits are for installation between cabinets only and
are not for end-of-cabinet installation.
Maximum cabinet depth above and beside the unit
is 13 inches.
When installing the oven beneath smooth,
fl
at
cabinets, be careful to follow the instructions on the
top cabinet template for power cord clearance.
For models with top venting holes: Do not allow
cabinetry or other objects to block the air
fl
ow of the
vent.
If the oven is to be vented outside, it is important
that venting be installed using the most direct
route and with as few elbows as possible. This
ensures clear venting of exhaust and helps prevent
blockages. Also, make sure dampers swing freely
and nothing is blocking the ducts.
Note:
The total duct length of 3¼" x 10" rectangular
or 6" diameter round duct should not exceed
140 equivalent feet. Refer to the Installation
Instructions (Hood Exhaust Section) for exhaust duct
preparation.
WARNING:
Risk of Electric Shock. Can cause injury
or death: THIS APPLIANCE MUST BE PROPERLY
GROUNDED to avoid severe or fatal shock.
A quali
fi
ed electrician must perform a ground
continuity check on the wall receptacle before
beginning the installation to ensure that the outlet
box is properly grounded. If not properly grounded,
or if the wall receptacle does not meet electrical
requirements noted (under Electrical Requirements),
a quali
fi
ed electrician should be employed to correct
any de
fi
ciencies.
The power cord of this appliance is equipped with
a three-prong (grounding) plug which mates with a
standard three-prong (grounding) wall receptacle to
minimize the possibility of electrical shock hazard
from this appliance.
Caution:
• For personal safety, the mounting surface must
be capable of supporting the cabinet load,
in addition to the added weight of this 63–85
pound product, plus additional oven loads of
up to 50 pounds or a total weight of 113–135
pounds.
• For personal safety, this product cannot be
installed in cabinet arrangements such as an
island or a peninsula. It must be mounted to
BOTH a top cabinet AND a wall.
• To avoid the risk of personal injury (back injury
or other injuries due to excessive weight of the
microwave oven) or property damage, you will
need two people to install this microwave oven.
Ensure proper
ground exists
before use
Electrical Requirements
Product rating is 120 volts AC, 60 Hertz, 15 amps
and 1.70 kilowatts. The outlet box should be located
in the cabinet above the oven and away from any
potential microwave oven ducting. The outlet box
and supply circuit should be installed by a quali
fi
ed
electrician and conform to the National Electrical
Code or the prevailing local code.