– 10 –
Operation and Cycle Information
This section of the guide provides details on segments of cycles, timing of cycles, temperature expectations
and cycling of the heater during the dry portion of a cycle.
Auto Hot Start
If incoming water temperature is below 80°F, Auto Hot Start is initiated at the beginning of the cycle in an
attempt to purge the home water lines of cooler water. Auto Hot Start can add up to 10 minutes to overall
F\FOHWLPH2QHDXWRKRWVWDUWVHJPHQWLQFOXGHVDPLQXWH¿OOPLQXWHFLUFXODWHDQGVHFRQGGUDLQ
repeating this sequence if the 80 degree temperature is not met. The dishwasher can repeat this up to 3
WLPHVLIQHHGHG,IWKHWHPSHUDWXUHLVPHWLQRQHRUWZRVHJPHQWVWKHF\FOHDGYDQFHVWRWKH¿UVWSUHZDVK
segment of the cycle.
Cycle Times
Times will vary depending on options selected, incoming water temperature, and soil level (some models).
Incoming water temperature of 120°F - 140°F is recommended. The 4 pass heating element quickly heats
the water for optimum performance.
The Cycle Chart below explains the segments of a cycle (cycles for all models included, not all models contain
VDPHF\FOHV,WGHWDLOV¿OODQGGUDLQWLPHVZKLFKGHSHQGRQHLWKHUDIXOORUSDUWLDOGUDLQ,WSURYLGHVWKH
circulation time in each segment, but does not include dry cycles (see the Dry System section in this guide).
Times will vary depending on turbidity response and incoming water temperature.
Cycle Algorithm Comparisons
Segment
Description
Diverter
Position
Zonal
Use
Calrod
Light
Normal
AutoSense
Heavy
Fixed
Light
Soil
Heavy
Soil
Light
Soil
Heavy
Soil
PW1
Fill (sec)
Circ (min)
Drain
Upper
No
OFF
60
5
Empty
60
5
Empty
60
5
Empty
60
5
Empty
60
5
Empty
60
5
Empty
PW2
Fill (sec)
Circ (min)
Drain
Lower
No
OFF
60
5.5
Empty
60
5.5
Empty
60
5.5
Empty
PW3
Fill (sec)
Circ (min)
Drain
60LSA/
60USA
No
OFF
60
4
None
60
5
Empty
60
5
Empty
60
5
Empty
PW4
Fill (sec)
Circ (min)
Drain
60LSA/
60USA
Yes
Shorten
~30%
ON
60
15
Empty
Main
Wash
Fill (sec)
Circ (min)
Drain
180USA/
180LSA
Yes will
Shorten
~30%
ON
0
20
Empty
60
41
Empty
60
40
Empty
60
40
Empty
60
45
Empty
60
45
Empty
60
45
Empty
PR1
Fill (sec)
Circ (min)
Drain
180LSA/
180USA
No on
Norm/
auto;
Yes on
Heavy
OFF
60
12
Empty
60
12
Empty
60
12
Empty
60
15
Empty
PR2
Fill (sec)
Circ (min)
Drain
60 LSA/
60 USA
No
OFF
60
4
Empty
60
5
Empty
60
5
Empty
60
5
Empty
60
5
Empty
60
5
Empty
0.8
5
Empty
Sani
Rinse
Fill (sec)
Circ (min)
Drain
Upper
No
ON
Final
Rinse
Fill (sec)
Circ (min)
Drain
60LSA/
120USA
No
ON
60
13
Empty
60
15
Empty
60
15
Empty
60
15
Empty
60
30
Empty
60
30
Empty
60
30
Empty
Summary of Contents for ADT521PGJ Series
Page 19: ... 19 Silverware Basket on Door Silverware Basket in Bottom Rack ...
Page 46: ... 46 Diagnostics Strip circuit ...
Page 63: ... 63 Diagnostics Drain Pump Strip Circuit ...
Page 68: ... 68 Schematics GDF520J GDF610J ...
Page 69: ... 69 GDT535J ...
Page 70: ... 70 ADT521J GDF610J GDF620J GDT545J GDT625J GDT635J ...
Page 72: ... 72 Upper Spray System 5 8 61 V Vent Parts 4 33 W Warranty 72 Water Level 4 45 ...