– 48 –
Thermistor
The
7KHUPLVWRULVORFDWHGLQVLGHWKHÀRRGVZLWFK
assembly. The thermistor monitors water
temperature in the tub. If the thermistor opens
or shorts it will cause a error (see Consumer Error
Mode). If it fails in open or shorted, the control will
default to the longest time algorithm
7RFKHFNWKHWKHUPLVWRUWKHÀRRGVZLWFKFDQEH
removed or checked by accessing the Main Control
(see To Access Main Control Board section), check
resistance on connector J711, pin 6 and pin 7.
Thermistor Strip Circuit
Flood Switch Pins
7KHUPLVWRU6SHFL¿FDWLRQV
Fill Funnel and Hose
The Fill Funnel is located on the left side of the
dishwasher tub and can be removed by turning the
¿OOIXQQHOFRXQWHUFORFNZLVHWZLVWORFNGHVLJQ7KHUH
LVDJDVNHWEHWZHHQWKH¿OOIXQQHODQGWXE7KH¿OO
KRVHFRQQHFWVWKHZDWHUYDOYHWRWKH¿OOIXQQHO
VOLTAGE
RESISTANCE
TEMPERATURE
.95
20066
50°F
1.56
10450
75°F
2.25
5824
100°F
2.91
3411
125°F
3.48
2081
150°F
3.91
1330
175°F
6 - 7 at Main Control
3 - 5 at Flood Switch
Summary of Contents for ADT521PGJ Series
Page 19: ... 19 Silverware Basket on Door Silverware Basket in Bottom Rack ...
Page 46: ... 46 Diagnostics Strip circuit ...
Page 63: ... 63 Diagnostics Drain Pump Strip Circuit ...
Page 68: ... 68 Schematics GDF520J GDF610J ...
Page 69: ... 69 GDT535J ...
Page 70: ... 70 ADT521J GDF610J GDF620J GDT545J GDT625J GDT635J ...
Page 72: ... 72 Upper Spray System 5 8 61 V Vent Parts 4 33 W Warranty 72 Water Level 4 45 ...