Concord 4 Series Systems
90
Appendix B:
Reference
Tables
Table B1: Sensor Group Characteristics
No.
Name
Application
Alarm
Delay
Res
tora
l
S
upe
rv
is
ory
CS Report
Ch
ime
(L
eve
l 1)
Active Le
vels
00
Fixed Panic
24-hour audible fixed emergency buttons.
Police
Instant
√
√
1, 2, 3
01
Portable Panic
24-hour audible portable emergency buttons.
Police
Instant
√
1, 2, 3
02
Fixed Panic
24-hour silent fixed emergency buttons.
Silent
Instant
√
√
1, 2, 3
03
Portable Panic
24-hour silent portable emergency buttons.
Silent
Instant
√
1, 2, 3
04
Fixed Auxiliary
24-hour auxiliary sensor, such as Pendant Panic or
holdup button.
Auxiliary Instant
√
√
1, 2, 3
05
Fixed Auxiliary
24-hour auxiliary emergency button. Siren shutoff
confirms CS report.
Auxiliary Instant
√
√
1, 2, 3
06
Portable Auxil-
iary
24-hour portable auxiliary alert button.
Auxiliary Instant
√
1, 2, 3
07
Portable Auxil-
iary
24-hour portable auxiliary button. Siren shutoff con-
firms CS report.
Auxiliary Instant
√
1, 2, 3
08
Special Intrusion Special belongings, such as gun cabinets and wall
safes.
Police
Instant
√
√
√
1, 2, 3
09
Special Intrusion Special belongings (i.e. gun cabinets and wall safes.) Police
Standard
√
√
√
1, 2, 3
10
Entry/Exit Delay
Entry and exit doors that require a standard delay
time.
Police
Standard
√
√
√
√
2, 3
11
Entry/Exit Delay
Garage doors and entrances that require an extended
delay time. *
Police
Extended
√
√
√
√
2, 3
12
Entry/Exit Delay
Driveway gates and entrances that require a twice
extended delay time. *
Police
Twice
Extended
√
√
√
√
2, 3
13
Instant Perimeter Exterior doors and windows.
Police
Instant
√
√
√
√
2, 3
14
Instant Interior
Interior doors.
Police
Follower
√
√
√
2, 3
15
Instant Interior
Interior PIR motion sensors. *
Police
Follower
√
√
2, 3
16
Instant Interior
Interior doors.
Police
Follower
√
√
√
3
17
Instant Interior
PIR motion sensors. *
Police
Follower
√
√
3
18
Instant Interior
Instant Interior Cross-Zone# PIR motion sensors. * †
Police
Follower
√
√
3
19
Delayed Interior
Interior doors that initiate a delay before going into
alarm. *
Police
Standard
√
√
√
3
20
Delayed Interior
PIR motion sensors that initiate a delay before going
into alarm. *
Police
Standard
√
√
3
21
Local Instant
Interior
24-hour local alarm zone protecting anything that
opens and closes.
Police
Instant
√
√
1, 2, 3
22
Local Delayed
Interior
Same as group 21, plus activation initiates a delay
before going into alarm.
Police
Standard
√
√
1, 2, 3
23
Local Instant
Auxiliary
24-hour local alarm zone protecting anything that
opens and closes. ‡
Auxiliary Instant
√
√
1, 2, 3
24
Local Instant
Auxiliary
24-hour local alarm zone protecting anything that
opens and closes. Sirens shut off at restoral. *
Auxiliary Instant
√
√
1, 2, 3
25
Local Special
Chime
Notify the user when a door is opened. Sounds emit
from a local annunciator. *
Special
Chime
Instant
√
1, 2, 3
WWW.DIYALARMFORUM.COM