AUX RS485+
MAIN RS485-
-
MAIN RS485+
8
7C
7
5C
6
6C
INTERCONNECT CARD
DATA
AUX
MAIN
ON
OFF
0
5
1
6
2
7
3
8
4
9
0
5
1
6
2
7
3
8
4
9
B
3
F
7
D
5
1
9
C
4
0
8
E
6
2
A
B
3
F
7
D
5
1
9
C
4
0
8
E
6
2
A
1's
10's
100's
PROTOCOL
FACTORY USE ONLY
0
5
1
6
2
7
3
8
4
9
0
5
1
6
2
7
3
8
4
9
B
3
F
7
D
5
1
9
C
4
0
8
E
6
2
A
B
3
F
7
D
5
1
9
C
4
0
8
E
6
2
A
1's
10's
100's
PROTOCOL
OFF
ON
OFF
MAIN
AUX
ON
TIPs
Equivalent values for the switches are:
•
For the
1’s
switch, the values increase
in increments of 1 from 0 to 9.
•
For the
10’s
switch, the values
increase in increments of 10 from 0
to 90.
•
For the
100’s
switch, the values
increase in increments of 100 from
0 to 900 for switch positions
0 through 9 and from 1,000 to 1,500
for positions A through F.
•
For the
PROTOCOL
switch, the values
are as follows:
Switch
Value
0
GE Digiplex (RS-422) @ 4800 baud
1
GE Impac (RS-485) @ 9600 baud
2
For future use
3
For future use
4
For future use
5
GE ASCII @ 9600 baud
6
Pelco D @ 2400 baud
7
Ultrak @ 9600 baud (even parity)
8
For factory use
9
For factory use
A
For future use
B
For future use
C
For future use
D
For future use
E
For future use
F
For future use
4 | Addressing and terminating
Addressing and terminating
The dome provides rotary switches for setting the camera’s site address and communication
protocol. Site addresses can be numbered from 0 to 1599. Termination is set with two slide switches.
Rotary switches
Termination
Note:
AUX is for future use.
5 = ASCII
5 = 500
2 = 20
1 = 1
address = 521
TIPs
•
Set termination to
ON
if the
dome or device is the final
receiver location.
•
Set termination to
OFF
if the
data signal is looping out to
other domes or devices.