higher priority alarm will override the lower
priority alarm. The lower priority alarm will
be restarted
only if
it is still being triggered
after the higher priority alarm has finished.
•
The only relay states that you need to clear
are those that are set to
Infinite
duration.
•
Clear
Infinite
duration relay states by:
(1) selecting a
Relay Off
button; (2) using
another alarm command that sets the relay
with a duration of at least one second; or
(3) using a remapped preset command that
activates a macro.
•
You can make a relay action a default action
upon the power-up of the dome by selecting
the
Relay 1 on
or the
Relay 2 on
button on
the
Relay State
screen.
To program an alarm:
1. Access the menus (page 5).
2. Select
Alarms
and
Contact Setup
.
3. Select a contact number.
4. Select a contact type.
5. Optional: Give the alarm a name.
6. Optional: Assign an alarm action.
7. Select an action number, if an action was
assigned.
8. Optional: Add one or two relay actions.
9. Select relay durations, if relays were added.
10. Complete steps 3 through 9 for additional
alarms.
11. Select
Priority
and arrange the priority of
the alarms from the highest to the lowest.
12 | Advanced programming - alarms
TIP
When changing settings on any program-
ming page, you need to confirm the new
settings by selecting
OK
on that page.
Alarms
You can program up to eight alarm inputs and
two relay outputs per dome. Each alarm input
can call up (display) any preset, macro
(programmed routine), or ShadowTour. Legend
domes do not handle alarms in the same way
as most other alarm equipment. You need to be
aware of the key differences. See the user
manual for complete details.
Key differences of dome alarms
•
Each dome alarm can include one dome action
(not required) and one or two relay actions.
•
The
Resume
feature is disabled by alarms.
•
Dome alarms are not acknowledged.
•
When a dome alarm is set to a preset, tour,
or macro, the camera will stay with that action
until the operator issues a command from the
keypad.
Resume
will then be reenabled.
•
Dome alarms are prioritized.
•
Dome alarms are not held in a queue. Only
the highest priority alarm that is triggered
is actioned.
•
If several dome alarms are triggered at the
same time, the next highest priority alarm is
actioned
only if
it is still being triggered after
the higher priority alarm has finished.
•
If a higher priority alarm is triggered while a
lower priority alarm is being actioned, the