NX-592E
Installation Manual
10
Power up
This section describes how to deliver power to both the module and panel and how to establish a
communication link between the two.
1. Verify that all wiring between the panel and module are correct.
2. Reconnect the backup battery and restore panel AC power.
Enrolling the module
The NetworX control panels have the ability to automatically find and store in memory the presence of all
keypads, zone expanders, wireless receivers, output modules, and any other device on the keypad bus. This
allows these devices to be supervised by the control panel. To enroll the devices, enter Program Mode using
the procedure outlined in the control panel installation manual. When you exit Program Mode, the control
panel will automatically enroll the devices. The enrolling process takes about 12 seconds, during which time
the “Service” LED will illuminate. User codes will not be accepted during the enrolling process. Once a
module is enrolled, if it is not detected by the control, the “Service” LED will illuminate. When initially
powering up, the control panel automatically performs the device enrollment process.
Programming using the keypad
The wireless gateway needs to know the address of at least one of the LCD keypads. Some commands, such as
getting the zone names for display on the website, will not work if the keypad address is not known. By
default, the wireless gateway assumes a keypad address of 192 (keypad 1, partition 1). If your LCD keypad is
programmed differently (press
*94
+
installer code
to check), you must change the wireless gateway keypad
address. To change the gateway keypad address, do the following:
1. Press
*
, then
8
.
2. Enter the “Go to program” code. The default code is
9
,
7
,
1
,
3
. If the code is valid, the keypad display
will prompt you for a device address.
3. Enter the address of the NX-592E, which is
7
,
8
, then press
#
. At this point, the keypad display will
prompt you for a programming location to be entered.
4. Enter
0
, followed by the
#
key. Location 0, which is the LCD address will display. The default is 192.
For a list of addresses, see
Table 4
on page 11.
5. To change the LCD keypad address, enter the new address, followed by the
*
. The display will return
to the location prompt.
6. To exit this location without changing the data, press the
#
key.
7. To review the data, repeat the above procedure, pressing the
*
key without entering data first. If you
attempt to program an invalid entry for a particular segment, the keypad sounder will emit a triple error
beep (beep, beep, beep) and remain in that segment awaiting a valid entry.
8. To exit Program Mode, press the
Exit
key to exit this programming level. Pressing the
Exit
key again
will exit the Program Mode.