Verifying dome software and AHC firmware versions
In order to operate Legend IP domes with Tyco/AD (RS-422) keypads, your domes must be installed with
v2.1.9 (or later) software and the active housing cards (AHCs) in the domes must be installed with v7 (or later)
firmware.
To verify the software version of the domes and the firmware version of the installed AHCs:
1. Select
System
and
Status
in the menus of the graphical programming interface. Refer to the Legend IP
User Manual
(1055713) for details about using the programming interface.
2. Scroll down to the
Site info
and
AHC info
sections.
Wiring Tyco/AD keypads to Legend IP domes
If your domes have the correct dome software and AHC firmware (
Verifying dome software and AHC
firmware versions
), then connect your Tyco/AD keypads to the data connections of the domes as shown in
Figure 44
and
Table 12
.
Be aware that you lose streaming position reporting out of the AUX ports while you have Tyco/AD keypads
wired to Legend IP domes.
Figure 44. Tyco/AD keypad wiring to Legend IP domes
Table 12. Tyco/AD keypad wiring to Legend IP domes
Legend IP data
(AHC v7 or later)
Tyco/AD data
(AD SV422 module)
AUX RS-485-
to
RXLO-
AUX RS-485+
to
RXHI+
MAIN RS-485/422-
to
TXLO-
MAIN RS-485/422+
to
TXHI+
AUX RS-485--
AUX RS-485+
MAIN RS-485/422--
MAIN RS-485/422+
TXLO--
TXHI+
RXLO--
RXHI+
Legend IP
data terminals
Tyco/AD data terminals
(AD SV422 module)
Summary of Contents for Legend IP
Page 1: ...Legend IP Installation Manual ...
Page 5: ...v Index 73 ...
Page 6: ...Legend IP Installation Manual vi ...
Page 28: ...Legend IP Installation Manual 20 ...
Page 38: ...Legend IP Installation Manual 30 ...
Page 48: ...Legend IP Installation Manual 40 ...
Page 54: ...Legend IP Installation Manual 46 ...
Page 68: ...Legend IP Installation Manual 60 ...