Chapter 3
Wiring and addressing the dome
39
Setting the termination
You must set the termination of the data signal in each dome (or device) to on or off. Only two of the four
switches (1 and 4) on the DIP are used (
Figure 17
). Switches 2 and 3 are not used at this time, so it does not
matter whether they are set to on or off. MAIN is for the dome input and AUX is for an auxiliary device output.
The AUX connections are wired only if you want streaming position reporting or are using the Tyco/AD
(RS-422) protocol. To wire a Tyco/AD (RS-422) keypad to the dome, see
Upgrading Legend to Legend IP
<<<waiting for card info>>>
on page 71. For details about streaming position reporting, see the Legend IP
User Manual
(1055713).
To set the termination, see
Figure 17
and do the following:
•
Set the termination to ON if the dome or device is the final receiver location for the data signal.
•
Set the termination to OFF if the data signal needs to loop out to other domes or devices.
Note:
The switches are set to ON by default. You need to turn them OFF if you are looping the data signal.
Figure 17. Termination switches
I/C
6
I/C
O/C
---
+
0
5
1
6
2
7
3
8
4
9
0
5
1
6
2
7
3
8
4
9
B
3
F
7
D
5
1
9
C
4
0
8
E
6
2
A
B
F
D
1
9
C
0
8
E
A
1's
10's
OFF
ON
AUX
MAIN
1
2
3
4
ON
OFF
ON
AUX
MAIN
1
2
3
4
ON
Termination switches
Summary of Contents for Legend IP
Page 1: ...Legend IP Installation Manual ...
Page 5: ...v Index 73 ...
Page 6: ...Legend IP Installation Manual vi ...
Page 28: ...Legend IP Installation Manual 20 ...
Page 38: ...Legend IP Installation Manual 30 ...
Page 48: ...Legend IP Installation Manual 40 ...
Page 54: ...Legend IP Installation Manual 46 ...
Page 68: ...Legend IP Installation Manual 60 ...