Passcodes off by default
Legend IP domes ship with the passcodes turned off. When you enter the programming interface for the first
time during installation and go to the
Passcode
page under the
Setup
menu, the passcode fields are blank.
Blank passcode fields mean the passcodes are turned off (disabled). You can choose to enter passcodes into the
blanks. This turns passcodes on (enables them) and a passcode will be required to enter the programming
interface the next time you try to access it.
The passcodes control who has access to the features of your dome (see
Turning on passcodes
). Only the
installer through the installer passcode has permission to turn on, turn off, or change the passcodes. If no
passcodes are programmed, all users are given installer access and are not required to log on. If only the Admin
and Operator passcodes are programmed, then anyone can still access the entire programming interface as an
installer, since the Installer passcode was not programmed.
Turning on passcodes
You can turn on one installer passcode, one admin passcode, and one operator passcode. They have the
following permissions:
Installer:
The installer passcode allows access to all dome features.
Admin:
The admin passcode allows access to all dome features, except passcodes and firmware
upgrades.
Operator:
The operator passcode allows no access until it is granted access to specific features on an
area-by-area basis.
To access the programming interface and turn on passcodes, do the following:
CAUTION:
If you use passcodes, record them in a secure place. If you forget the passcodes for a dome, you will need to
send the dome back to the factory so that it can be reset by the factory with no passcodes.
1. At the normal display, press and hold the
set
(
) key on the keypad until you hear a beep
and the programming code display appears
on the keypad’s LCD.
Figure 21. Normal display (programming interface accessed)
2. At the
ENTER PROGRAMMING CODE
display, enter the programming access code
by pressing the
9
,
5
,
1
, and
seq
keys.
This code is the same for all GE keypads.
Figure 22. ENTER PROGRAMMING CODE display
CAMERA 1
MONITOR 1
ENTER PROGRAMMING
CODE: _
Summary of Contents for Legend IP
Page 1: ...Legend IP Installation Manual ...
Page 5: ...v Index 73 ...
Page 6: ...Legend IP Installation Manual vi ...
Page 28: ...Legend IP Installation Manual 20 ...
Page 38: ...Legend IP Installation Manual 30 ...
Page 48: ...Legend IP Installation Manual 40 ...
Page 54: ...Legend IP Installation Manual 46 ...
Page 68: ...Legend IP Installation Manual 60 ...