Chapter 1
Introduction
11
Power requirements
All Legend IP domes require a 24 VAC power supply to operate the domes’ PTZ, camera, and heater/blower,
if present. The startup and running power requirements vary depending on the model (
Table 3
).
Be aware that Legend IP domes have greater power requirements than do CyberDome or analog Legend
domes, which may require upgrading the power cabling for Legend IP domes.
Power cable size and length requirements
Using the proper gauge of power cable will ensure proper operation and avoid voltage drops. See
Table 4
for the
recommended cable gauge for varying maximum cable lengths for the different models of domes.
CAUTION:
Use only a Class 2 power supply of the required output rating as listed on individual units and specified.
Table 3.
Power requirements at 24 VAC (±4 VAC) operating voltage
Model
Start-up power
Running power
Dome without heater/blower
30 W
24 W
Dome with heater/blower
60 W
44 W
Rugged and HD dome with 25 W heater/blower
100 W
74 W
Table 4.
Recommended power cable gauges based on maximum lengths for an operating voltage of 24 VAC (±4 VAC)
Wire gauge
Domes without
heater/blower
(30 W)
Domes with
heater/blower
(60 W)
HD domes with
heater/blower
(100 W)
AWG
mm
2
feet
meters
feet
meters
feet
meters
10
2.60
1565
477
780
238
470
143
12
2.05
985
300
490
149
295
90
14
1.62
620
189
310
94
185
56
16
1.29
390
119
195
59
115
35
18
1.02
245
75
120
37
70
21
20
0.81
150
46
75
23
45
14
22
0.64
95
29
45
14
25
8
Summary of Contents for Legend IP
Page 1: ...Legend IP Installation Manual ...
Page 5: ...v Index 73 ...
Page 6: ...Legend IP Installation Manual vi ...
Page 28: ...Legend IP Installation Manual 20 ...
Page 38: ...Legend IP Installation Manual 30 ...
Page 48: ...Legend IP Installation Manual 40 ...
Page 54: ...Legend IP Installation Manual 46 ...
Page 68: ...Legend IP Installation Manual 60 ...