05-4446A01, Rev. E
Mercury Reference Manual
85
Invisible place holder
Figure 3-49. Point-to-Multipoint Serial-to-Serial Application
Diagram
Invisible place holder
192.168.0.3
192.168.0.4
EIA-232
Terminal
or Computer
RTU
RTU
RTU
EIA-232
EIA-232
EIA-232
192.168.0.10
192.168.0.1
192.168.0.2
Access Point
LA
N
COM
1
COM
2
PW
R
LIN
K
Remote
LA
N
COM
1
COM
2
PW
R
LIN
K
Remote
LA
N
COM
1
COM
2
PW
R
LIN
K
Remote
Table 3-6. Serial Port Application Configuration
Transceiver Location
Menu Item
Setting
Access Point (COM1)
Status
Enabled
Baud Rate
9600 (Example)
Flow Control
Disabled
IP Protocol
UDP
Remote IP Address
224.254.1.1—
Multicast Address
1
Remote IP Port
30010
Local IP Port
30010
Remote Units (COM1)
Enable
Enabled
Baud Rate
2,400 (Example)
Flow Control
Hardware (Example)
IP Protocol
UDP
Remote IP Address
192.168.0.1
Remote IP Port
30010
Local IP Port
30010
Local Multicast
Address
224.254.1.1 —
Multicast Address
2
1. This address is an example only. Any Class D IP address
(224.0.0.0—239.255.255.255) will work.
Summary of Contents for Mercury 900
Page 9: ...viii Mercury Reference Manual 05 4446A01 Rev E...
Page 11: ...2 Mercury Reference Manual 05 4446A01 Rev E...
Page 31: ...22 Mercury Reference Manual 05 4446A01 Rev E...
Page 155: ...146 Mercury Reference Manual 05 4446A01 Rev E...
Page 157: ...148 Mercury Reference Manual 05 4446A01 Rev E...
Page 171: ...162 Mercury Reference Manual 05 4446A01 Rev E...
Page 185: ...176 Mercury Reference Manual 05 4446A01 Rev E...
Page 201: ...192 Mercury Reference Manual 05 4446A01 Rev E...