66
Downloader Programming
The panel can be programmed remotely using ToolBox. Use the information you recorded in
Appendix A to inform the downloading operator of the programming requirements for this sys-
tem.
ToolBox Downloader Programming
Note
A Downloader Phone Num-
ber must be programmed
and the user-programmable
option “Downloading” must
be on for remote downloader
programming to work.
¾
To initiate a ToolBox download session:
1.
Contact your download station and ask the operator to prepare to download to the panel.
2.
Make sure the system is disarmed.
3.
Press 8
+
system master code
+
7
+
0 (any)
,
1 (down)
,
or
2 (up). The display shows
SYSTEM
DOWNLOAD IN PROGRESS
during the downloading process.
If the alphanumeric touchpad does not display
SYSTEM DOWNLOAD IN PROGRESS
,
call the down-
loader operator to verify the downloader phone number. Also, make sure ToolBox is set up prop-
erly. Refer to the “Troubleshooting” section if the problem persists.
Testing the
System
This section describes the following:
•
Basic System Commands
•
Testing Zones/Sensors
•
Testing Phone Communication
•
Testing Central Station Communication
•
Testing Outputs and Sirens
Note
Before testing, it is recom-
mended that you have cov-
ers on all modules (mounted
outside the cabinet) and the
panel cabinet door closed.
The testing environment
should match the system
working environment.
•
Testing Light Control
•
Testing the Energy Saver Module
•
Changing Fixed Display Touchpads
•
Testing the Audio Verification Module
•
Testing Cellular Backup Communication
You should test the system after installing or servicing and after adding or removing devices from
the system.
Refer to the “Troubleshooting” section if correct test results are not achieved.
Basic System Commands
Table 9 describes basic touchpad operating commands. For complete details on system operation,
including user programming, refer to the system
User’s Manual
.
Table 9: Basic Touchpad Commands
Command
System Response
* (STATUS)
Indicates current system status
* + *
Indicates AC power and battery status
1 + CODE
Disarms system to OFF
2 + CODE
Arms system to STAY
3 + CODE
Arms system to AWAY
2 (quick arm on)
Arms system to STAY
3 (quick arm on)
Arms system to AWAY
2 or 3 + CODE + 4
or
2 or 3 + 4
Arm system—No Delay (no exit or entry delay)
5 + 2 or 3 + CODE
or
5 + 2 or 3
Arms system silently (no arming status beeps)
7 + 1
Turns chime feature on and off
7 + 2
Turns Energy Saver on and off
7 + 6
Identifies alarms in memory