![GE Interlogix 60-734-01 Installation Instructions Manual Download Page 51](http://html.mh-extra.com/html/ge-interlogix/60-734-01/60-734-01_installation-instructions-manual_571942051.webp)
Concord
46
The following sections describe the settings that appear under
REPORTING—PARTITION 1-2
.
Program Report (06015)
Reporting-Global (Default = off)
When this setting is on, the panel sends a report to the central sta-
tion when someone enters or exits installer programming.
¾
To turn Program Report on or off:
1.
With the display showing
PROGRAM REPORT ON/
OFF
(current setting)
, press 1 (off) or 2 (on). The
display flashes the entered setting.
2.
Press # and the display shows the new setting.
Opening Reports (partition 1: 06100, partition 2: 06200)
Reporting-Partition 1-2 (Default = off)
When this setting is on, the panel sends an opening report to the central
station after disarming the system.
Note
To use this feature, the Open/Close Reports settings under the
PHONES
menu must be turned on for the specific CS Phone or Pager number.
¾
To turn Opening Reports off or on:
1.
With the display showing
OPENING REPORTS
OFF/ON
(current setting)
, press 1 (off) or 2 (on).
The display flashes the entered setting.
2.
Press # and the display shows the new setting.
Closing Reports (partition 1: 06101, partition 2: 06201)
Reporting-Partition 1-2 (Default = off)
When this setting is on, the panel sends a closing report to the central
station after arming the system.
Note
To use this feature, the Open/Close Reports settings under the
PHONES
menu must be turned on for the specific CS Phone or Pager number.
¾
To turn Closing Reports off or on:
1.
With the display showing
CLOSING REPORTS
OFF/ON
(current setting)
, press 1 (off) or 2 (on).
The display flashes the entered setting.
2.
Press # and the display shows the new setting.
Recent Closings (partition 1: 06102, partition 2: 06202)
Reporting-Partition 1-2 (Default = on)
When this setting is on, the panel sends a recent closing report to the
central station if an alarm occurs within two minutes
after
the exit
delay time expires. Such a report is used to identify a possible exit
fault.
¾
To turn Recent Closings off or on:
1.
With the display showing
RECENT CLOSINGS
OFF/ON
(current setting)
, press 1 (off) or 2 (on).
The display flashes the entered setting.
2.
Press # and the display shows the new setting.
No Activity (partition 1: 06103, partition 2: 06203)
Reporting-Partition 1-2 (Default = off)
When this setting is on, the panel sends a no activity report to the cen-
tral station when the activity timeout expires (see
TIMERS—ACTIVITY TIM-
EOUT
).
¾
To turn No Activity reports off or on:
1.
With the display showing
NO ACTIVITY OFF/ON
(current setting)
, press 1 (off) or 2 (on). The dis-
play flashes the entered setting.
2.
Press # and the display shows the new setting.
Duress Option (partition 1: 06104, partition 2: 06204)
Reporting-Partition 1-2 (Default = off)
(Default = off) When this setting is on, the system can be controlled
using a programmed duress code (see
SECURITY—PARTITION N—DURESS
CODE
).
Note
For UL Listed installations, Duress Option must be set to off.
Do not use a duress code unless it is absolutely necessary. Using duress
codes often results in false alarms due to code entry errors. If a duress
code
is
absolutely necessary, use it with the audio verification module
to reduce false alarms and accidental dispatches.
¾
To turn Duress Option off or on:
1.
With the display showing
DURESS OFF/ON
(cur-
rent setting)
, press 1 (off) or 2 (on). The display
flashes the entered setting.
2.
Press # and the display shows the new setting.