Note
For best results, it is recom-
mended that you crimp a
spade lug on the wire end at
the panel and secure the lug
under the circuit board
screw as shown in Figure 5.
Connecting the Panel to Earth Ground
For maximum protection from lightning strikes and transients, connect the lower-left circuit
board screw to earth ground as shown in Figure 5. Use 16-gauge, solid copper wire from an earth
grounded cold water pipe clamp to the panel.
Figure 5. Connecting the Panel to Earth Ground
Note
The lower header has two
jumpers installed from the
factory that must be
removed before installing
the Power Line Carrier Card.
Leave these jumpers in
place if you are not installing
a Power Line Carrier Card.
Installing the Optional Power Line Carrier Card (60-755)
The Power Line Carrier card lets you add Supervised Wireless Sirens for alarm and status sounds
and X10 Lamp Modules for controlling lights.
Install the card on the header pins as shown in Figure 6. No wiring or programming is necessary.
Figure 6. Installing the Power Line Carrier Card
Installing the Optional Phone Supervision Card (60-789)
The Phone Supervision Card allows the panel to check the phone line voltage (partition 1 only),
upon dialing the central station/pager number. The panel can also be programmed to check the
phone line voltage automatically (see “Line Fail Delay”)
Install the card on the header pins as shown in Figure 7.
Figure 7. Installing the Phone Supervision Card
To Water Pipe
Pipe
Ground Clamp
Power Line Carrier Card
Mounting Location
Jumpers
Terminal Strip
Power Line Carrier
Card Headers
Phone Supervision Card
Terminal Strip
Phone Supervision Card Headers