MDS 05-6399A01, Rev. F
MDS™ Master Station
5
The RF safety distance is calculated based on each product type’s highest output power
configuration with no duplexer, redundant switching, or cable losses.
Table 1-1 Antenna Gain vs. Minimum RF Safety Distance
Radio Module Equipped
Antenna Gain
0
–5 dBi
5
–10 dBi
10
–16.5 dBi
SDM4
– FCC
1.09 meters
1.95 meters
4.11 meters
SDM4
– IC
1.43 meters
2.54 meters
5.37 meters
SDM9
– FCC
0.99 meters
1.76 meters
3.73 meters
SDM9
– IC
1.29 meters
2.30 meters
4.87 meters
LN4
1.43 meters
2.54 meters
5.07 meters
LN9
1.08 meters
1.92 meters
3.82 meters
(other models):
Consult factory prior to operation.
Not all frequency models available. Consult factory for available models.
Antennas with gain greater than 16dBi have not been authorized for use with the EUT; and (b)
installation of the EUT into portable applications with respect to RF compliance will require
SAR testing and Regulatory approval.
CSA Notice
Units (Both AC and DC supply versions) are permanently connected to
Protective Earth, via ground stud on the unit enclosure back, where the final
installation is subject to acceptance of CSA International or the local inspection authority having
jurisdiction.
Conditions of Acceptability
:
1.
The equipment shall be installed indoors in a restricted access
location.
2.
Installation of the equipment and its modules shall be conducted by
trained personnel in accordance with the electrical code.
3.
This equipment is movable, Class I (earthed), pluggable Type A,
using detachable power cords, intended for use on TN or TT power
system for the AC power option.
4.
The DC power option shall be connected to an approved power
source with adequate protection, isolated from the mains by
reinforced insulation.
5.
This product was certified for use on a 20A branch circuit for the AC
power option.