DU-WS-0004-59 Rev A 6/15/11 GCX Corp. Page 2 of 9 

 

Parts Reference: 

The following parts and hardware are included in this kit (hardware not shown).  

 

Item # 

Description 

QTY 

VH M 

Folding L Bracket with Hardware 

Display Mount with Hardware 

Adjustable Channel Stop 

Wall Channel Cover 

3mm Hex Wrench 

1/8 Hex Wrench 

5/32 Hex Wrench  

1/2” Socket Wrench 

10 

Mouse Trap 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation Note: 

Assembly and Installation of this VHM wall mount kit should be followed in the sequence listed in this 

Installation Guide. Please read this Installation Guide prior to installing or using this product. 
 

 

 

1

 

10

 

Summary of Contents for VHM Series

Page 1: ...rpose of this guide is to Describe parts contained within this kit page 2 Describe installing Adjustable Stop page 3 Describe installing VHM Arm page 3 Describe attaching Folding L Bracket and Keyboar...

Page 2: ...play Mount with Hardware 1 4 Adjustable Channel Stop 1 5 Wall Channel Cover 1 6 3mm Hex Wrench 1 7 1 8 Hex Wrench 1 8 5 32 Hex Wrench 1 9 1 2 Socket Wrench 1 10 Mouse Trap 1 Installation Note Assembly...

Page 3: ...e to desired mounting position and tighten center screw Installing VHM Arm into Channel 1 Guide the Slide rear of Arm into top of the Channel and lower Arm to desired height Tighten the 4 Set Screws w...

Page 4: ...ll Keyboard Tray in accordance with separate Installation Guide supplied with Keyboard tray Folding L Bracket VHM Arm 5 32 Hex Wrench 2 1 4 28 x 3 4 FHSCS CAUTION Do not place fingers in between Foldi...

Page 5: ...upper and lower nylon washers should be positioned against the Folding L Bracket The 4 upper and lower metal Flat Washers should be positioned against the Display Mount Adjustment Knob and the 5 16 Lo...

Page 6: ...this procedure 1 Grasp the Arm behind the mounted instrument s to prevent sudden upward motion Carefully unlock the Arm and move it to a horizontal position that allows access to the Adjuster Cover be...

Page 7: ...a 1 2 wrench on each end of the bolt tighten or loosen bolt until desired tension is achieved Adjusting Swivel Tension 1 To adjust the swivel tension tighten or loosen the Swivel Tension Nut with a 3...

Page 8: ...hown are provided for routing cables along the Wall Channel Please refer to installation guide DU UT 0001 20 included with Channel Covers Cable Guides 2 snap into grooves on the underside of the Arm a...

Page 9: ...ith most mild non abrasive solutions commonly used in the hospital environment e g diluted bleach ammonia or alcohol solutions 2 The surface finish will be permanently damaged by strong chemicals and...

Reviews: