GCI E84 Emulator Getting Started Manual
Version 2.4a
GCI E84 Emulator Getting Started Manual
9
Continuous Mode Test Setup Screen
Continuous Handoff Test Setup Screen
The
Continuous Mode Test Setup Screen
is used to
configure Continuous Handoff Mode tests. The
Continuous Mode Test Setup Screen
is divided into
several sections.
Data entry fields allow the user to enter details about
the equipment being tested.
Active Mode timeouts are entered in the three
ACTIVE
EQUIPMENT TIMER SETTINGS
box fields (
TA
1,
TA
2,
TA
3).
Passive Mode timeouts are entered in the six
PASSIVE
EQUIPMENT TIMER SETTINGS
box fields (
TP
1,
TP
2,
TP
3,
TP
4,
TP
5,
TP
6). Delay timer settings are entered in the
C
ONTINUOUS
M
ODE
D
ELAY
T
IMER
box field (TD1).
A
COMMENTS
field is also provided to allow the user to
enter test specific comments.
All fields (with the exception of the
COMMENTS
field) must be entered before automated testing can begin.
The bottom right side of the screen lists check-off boxes to select pre-defined Continuous Mode Tests
provided by the
E84 Emulator
. The user simply checks off the desired tests. Next to each test definition
on the right side of the screen is a field that shows the current test results for each test. Initially, the fields
are empty since no tests have been run. Once each test is executed, the individual test results (Pass,
Fail, Untested) are displayed in these fields. For details on the available Continuous Mode tests, see the
Test Plans
section towards the end of this manual.
Defining the Continuous Mode Test Sequence List
A D
EFINE
C
ONTINUOUS
M
ODE
T
EST
S
EQUENCE
box allows the user to define the specific order of handoff’s
to run during Continuous Handoff Mode testing. This box contains an A
VAILABLE
C
YCLES
list, a set of
D
EFAULT
C
YCLE
buttons, the current set of selected handoff’s (S
ELECTED
C
YCLES
list), a Clear List button,
an Add Cycle button, a Remove Cycle button, and two sorting buttons (Move Up, Move Down) displayed
as arrows.
S
ELECTED
C
YCLES
List
This field shows the list of currently selected handoff’s. When running test A (active mode), this list
defines the sequence of handoff’s requested by the
E84 Emulator
acting as the active equipment. When
running test C (passive mode), this list defines the sequence of handoff’s the
E84 Emulator
expects to
see when acting as the passive equipment. When running test B (TP6 Timeout Error), the first handoff in
the list is requested by the
E84 Emulator
, after which the TP6 timeout error is verified.
At least one handoff must be placed in this list before testing can begin.
A
VAILABLE
C
YCLES
List
There are four available handoff’s: Load CS_0, Unload CS_0, Load CS_1, Unload CS_1. Double-clicking
one of these cycles will add that cycle to the S
ELECTED
C
YCLES
list.
Add / Remove Buttons
The Add and Remove buttons are located between the A
VAILABLE
C
YCLES
list and the S
ELECTED
C
YCLES
list, and take the shape of right and left arrows respectively. To Add a cycle, single click the desired cycle
in the A
VAILABLE
C
YCLES
list (the selected cycle will be highlighted in blue) and click the Add (right arrow)
button. The selected cycle will be added to the S
ELECTED
C
YCLES
list.
Summary of Contents for E84
Page 1: ...GCI E84 Emulator Getting Started Version 2 4a...
Page 2: ......