deemed  delivery,  or  such  shorter  time  as  may  be  specified  in  the  quotation.  Goods 
returned  to  GCE  will  not  be  accepted  unless  GCE  written  consent  to  their  return  has 
previously been obtained. 
The liability of the regulator is irrevocably transferred to the owner or operator to the extent 
that it is modified, serviced or repaired by personnel not employed or authorised by GCE or if 
the apparatus is used in a manner not conforming to its intended use. 
GCE cannot be held responsible for the misuse of the equipment in case of non-application 
of the instructions for use. 
 
APPENDIX :  
Nr 1- Technical and performance data  
Nr 2 - Quick coupling feature and connecting/disconnecting procedure 

 
 

 

Manufactured by 

GCE s.r.o. 

Zizkova 381 
583 81 Chotebor 
Czech Republic 

 
Tel :  +420 569 661 111 
Fax : +420 569 661 602 

http://www.gcegroup.com 

© GCE s.r.o. 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for mediline MEDIREG II

Page 1: ...Regulators IFU GB FR DE NL Rev 03 Page 1 44 12 02 2010 MEDIREG II MEDISELECT II MEDICAL HIGH PRESSURE REGULATORS Document Nr 735 800 000 092 Date of issue 12 02 2010 Revision Nr 3 GB FR DE NL...

Page 2: ...thing helium carbon dioxide xenon specified mixtures of the gases listed air or nitrogen to power surgical tools Operations Transport Storage Keep the product and its associated equipments away from h...

Page 3: ...alve due to that the gas is going from high pressure to low pressure Joule Thompson effect Ensure that all equipment that is connected to the valve by at least a 2 metre hose According to Medical Devi...

Page 4: ...the pressure outlet can be used Pressure outlet I is fitted with a gas specific medical quick connector also called quick coupler The user can connect another piece of equipment to this outlet with a...

Page 5: ...nto the cylinder valve connector Turn the regulator into the correct position for use and tighten the nut by hand do not use tools Pin index connection Position the pin index over the cylinder valve w...

Page 6: ...sition Do not use excessive force Reset the flow control knob to on the ZERO position once the gas flow stops and the regulator is vented For regulators fitted with a pressure outlet ensure it is func...

Page 7: ...position Ensure that the accessory is connected to the flow outlet Slowly open the cylinder valve by turning the hand wheel in anticlockwise direction approx 1 to 1 turns Sudden opening of the cylind...

Page 8: ...hand wheel in a clockwise direction to the stop position Do not use excessive force Reset the flow control knob on the ZERO position when the gas venting has ceased valid for version with flow meterin...

Page 9: ...ears At the end of the product s life time the product must be withdrawn from service The owner shall put in place a relevant procedure to ensure the product cannot be used again 2 Repairs activities...

Page 10: ...pressure range P2 Outlet pressure P4 Max outlet pressure closing pressure Q Outlet flow Service or disposal date The serial number indicates the year the product has to undergo the overall maintenance...

Page 11: ...ent that it is modified serviced or repaired by personnel not employed or authorised by GCE or if the apparatus is used in a manner not conforming to its intended use GCE cannot be held responsible fo...

Reviews: