PLACEMENT
Environment is to be clean, dry, and indoors. Unit is to remain above floor (rack and 4 wheel casters are provided). The Easy Series is
designed to fit under a counter as a corner unit or next to an existing under counter item. The Easy Series System should be located
in a climate controlled
environment
where it is protected from extreme hot or cold temperatures. The Easy Series System has been
designed with a compact 18” x 24” footprint and 29.5” height, for under the counter placement. The System must be easily accessed
for monitoring and service. Service area must permit access to all of the filter housings for removal and replacement of elements or
cartridges.
INSTALLATION NOTES
1. Lines to POU: espresso machines, coffee brewers, water tower, and ice machine lines are owner plumbed.
Lines to Points Of Use
(POU) are to be Owner-Plumbed. Never include toilets, sinks, or dipper well.
2. Owner supplied shut off ball valves at city feed, Easy Series out, filtered water out, and bypass as shown in typical shut off detail.
Pipe and valve size must match site requirements.
3. Owner to provide G.F.C.I electrical outlet.
4. The drain line must be attached and installed according to local city code. Usually with an air gap that has an unobstructed
vertical distance through free atmosphere between the lowest opening from any pipe, plumbing fixture, appliance or other piece
of equipment conveying waste to the flood level rim of the receptor. The vertical distance between the conveyor and receptor
shall be no less than 1 inch.
5. Installation must comply with existing local plumbing codes. Air gaps must comply with drawings or an approved air gap device
may be used. In addition some local plumbing codes require back flow devices. Both the air gap device and back flow device are
not supplied as part of the unit. These devices are available through your standard plumbing supply house.
*Alternate Bypass: If preferred, owner/installer is to provide plumbing of ball valve (shut-off-bypass) on wall as pictured
above. Points of use may be pre-plumbed as a single line through wall with manifold afterward.
6. RO equipment must not be plumbed to dipper well, toilets or wash sinks. They are to be on city water only.
7. OPC to provide plumbing configuration for RO: 3/4” pipe to 1/2” FIP threaded copper fitting on two (2) shut-off ball valves with
by-pass ball valve.
8. OPC to provide plumbing configuration for Drain w/ 1/2” FIP fitting. Drain into indirect waste .
9. Installer to provide 110 vac 15 amp GFCI plug for RO/Softener Systems.
10. A 20” x 48” (508mm x 1219mm) equipment stand is supplied with unit. Allow clearance indicated in drawing for rough plumbing
layout.
INSTALLATION PRECAUTIONS
•
The Easy 360/720 System must be installed with the inlets/outlets/drain as shown. Do not to reverse connections.
• Do not install on hot water line.
•
Maximum temperature allowed is 80°F (38°C).
•
A pressure regulator is required on incoming water pressure over 75 psi.
•
Use Teflon tape for connections. Do not use wicking or sealer for fitting connections.
•
Do not use torch or other high temperature sources near filter, cartridges, or any plastic fittings and pipes.
•
Installation must comply with existing local plumbing codes.
•
Do not install in direct sunlight.
•
Protect from freezing. Do not install in area that will drop to 32°F (0°C) or below.
•
Allow minimum service clearance space as shown in layouts to facilitate routine maintenance.
•
Mount System in a position and location so as to prevent system from being struck by items.
Lines to Points Of Use (POU) are to be owner plumbed. Never include toilets, sinks, or dipper well. Never hook RO up to hot water.
Installation
Easy AB Formulator - Unit Guide
Page 4