![GBD KUDA 150 Instructions For Installations Download Page 30](http://html2.mh-extra.com/html/gbd/kuda-150/kuda-150_instructions-for-installations_3833829030.webp)
PC200
Description
DIP
Status
Function
9 - DIP SWITCH SW1
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
Disables the deceleration function.
DIP 1
Enables deceleration during opening and closing.
The deceleration speed is adjusted with the DIP switch SW2_6.
ON
DECELERATION
OFF
DIP 2
DIP 3
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ANTI-CRUSHING
THRESHOLD
Very high sensitivity.
High sensitivity
Medium sensitivity
Low sensitivity
DIP 4
DIP 5
DIP 6
OFF
OFF
OFF
PAUSE TIME
Automatic closing disabled.
OFF
OFF
ON
3 seconds.
OFF
ON
OFF
10 seconds.
OFF
ON
ON
20 seconds.
ON
OFF
OFF
40 seconds.
ON
OFF
ON
60 seconds.
ON
ON
OFF
120 seconds.
ON
ON
ON
300 seconds.
8- WARNING LEDs
Description
Position
Colour
Signal
Short flash every second: at rest in one-motor mode.
Double flash every second: at rest in two-motor mode.
Long flash every second: during time learning.
On fixed: gate travel learning procedure not executed or failed.
Comes on when the START or PEDESTRIAN control is activated from the terminal
board or the receiver.
Always off. Comes on when the contact of terminal 20 is opened.
LED1
LED2
LED3
RED
RED
RED
-
START-PED
PHOT 1
LED4
RED
PHOT 2
Always off. Comes on when the contact of terminal 23 is opened.
LED5
RED
Receiver
Always off. Comes on when receiving a signal from the receiver.