8 - TIMES LEARNING
PRELIMINARY WARNINGS:
Values loaded by default:
- Working time: 60 s;
- Pause time : 30 s;
Be sure that the shutter is completely closed before making the learning procedure.
• Check the correct position of the limit switch.
Ÿ
Ÿ
automatic closing require 2 different procedures.
Ÿ
The learning of working time and
PROGRAMMING OF THE AUTOMATIC RECLOSING TIME:
• When the shutter is closed, put DIP2 in ON, then DIP3 in ON
Ÿ
LED DL9 will turn on fixed.
• Give any command (OPEN / CLOSE/ START)
Ÿ
An acoustic signal will show the beginning of pause time counting, LED DL9 will start blinking every second
• After the required time (MAX. 180 s), give any command (OPEN / CLOSE/ START);
Ÿ
A double acoustic signal and LED DL9 turning off will show that the operation has been successful;
Ÿ
Put DIP 3 in OFF
PROGRAMMING OF THE WORKING TIME:
• When the shutter is closed, put DIP2 in OFF, then DIP3 in ON
Ÿ
LED DL9 will turn on fixed.
• Give any command ( OPEN / CLOSE/ START);
Ÿ
The shutter will start the opening phase, LED DL9 will turn off and an acoustic signal will show the beginning of
the opening time counting.
Ÿ
The intervention of a photocell / edge will be irrelevant;
• On reaching the opening limit switch or after any command (OPEN / CLOSE/ START), the motion
will block;
Ÿ
LED DL9 will turn on fixed.
• Give any command ( OPEN / CLOSE/ START)
Ÿ
The shutter will start the closing phase and LED DL9 will turn off .
Ÿ
The intervention of a photocell / edge will temporarly block the counting and the closing manoeuvre of the
shutter, it is necessary to start again from the previous point.
• On reaching the closing limit switch or after any command ( OPEN / CLOSE/ START), the closing motion will
block;
Ÿ
LED Dl9 will turn on fixed and the control unit will emit a double acoustic signal, showing that the
operation has been successful.
Ÿ
Put DIP 3 in OFF.
Ÿ
Put DIP 2 to the original state.
IT
IT
UK
SR302
17
UK
SR302
16
9 - TRANSMITTERS PROGRAMMING
DOMINO, MAKO, GIOTTO TRANSMITTERS:
Operation with ONE BUTTON
!
Push the SW2 button for one second, after releasing it the control unit will emit an acoustic signal and LED
DL10 will turn on fixed;
!
Push in 10 s the transmitter button you want to store as START command, a triple acoustic signal with 3 LED
DL10 flashes will show the storage has occured;
!
Push in 10 s the button of the new transmitter you want to store.
!
After the learning of last transmitter, wait for a double acoustic signal and LED DL10 off, showing the end of the
procedure.
Operation with TWO BUTTONS:
!
Push the SW2 button for one second, after releasing it the control unit will emit an acoustic signal and LED
DL10 will turn on fixed.
!
Push in 10 s the transmitter button you want to store as OPEN button, a triple acoustic signal with 3 LED DL10
flashes will show the storage has occured.
!
Push in 10 s another button of the same transmitter to which you want to match the CLOSE function, a triple
acoustic signal with 3 LED DL10 flashes will show the storage has occured.
!
Repeat in 10 s the sequence of buttons pushes to store a new transmitter.
!
After the learning of last transmitter, wait for a double acoustic signal and LED DL10 off, showing the end of the
procedure.
NOTE: It is possible to store again a transmitter to switch from 1 button operation to 2 buttons and vice-
versa.
The double buttons mode is possible only if the 2 buttons of the transmitter are stored during the
same learning cycle, one after the other.
EWSETX... SERIES TRANSMITTERS:
!
Push the SW2 button for one second , after releasing it the control unit will emit an acoustic signal and LED
DL10 will turn on fixed;
!
Push in 10 s any button of the transmitter you want to store:
OPEN
function will be automatically assigned to
“Up arrow”
button,
CLOSE
function to “
Down arrow
” button and
STOP
function to
“Control unit”
button.
!
Push in 10 s the button of the new transmitter you want to store.
!
After the learning of last transmitter, wait for a double acoustic signal and LED DL10 off, showing the end of the
procedure.
NOTE: The assignment of the buttons is automatic and it is not possible to modify it.
COMPLETE CANCELLATION OF THE MEMORY
Push Sw2 button (LED L10 is on), keep pushing it as long as LED DL10 will make 10 flashes with 10 acoustic
signals.
DIP 7
ON
OFF
UNUSED
Unused
OFF
TERMINALS
13-14
MANAGEMENT
DIP 8
START command is associated with terminal 14, as terminal 13 is disabled.
OPEN command is associated with terminal 14 (the control unit will open but
won’t automatically close,even if the automatic closing is enabled),
as CLOSE command is associated with terminal 13.
ON
The transmitters buttons already stored can be over-written at any time.
It is possible to store 31 buttons or transmitters max.