Location Requirements:
WARNING:
This grill is Design Certified for use outdoors
only and is not intended for use on recreational
vehicles or boats.
The “Infrared Elite” is designed to be attached to the optional
pedestal / cart or be permanently installed on a free-standing
masonry or other suitable patio fixture.
Minimum clearance of a mobile grill to any adjacent
combustible construction can be found in Table A.
Table A.
If you are installing your grill as a brick-in or masonry supported
variation, it should be located so the ventilation louvers remain
clear of all obstructions. The louvers are located in the front face
of the grill and at the rear of the hood. Accumulation of debris in
the louvers can cause the grill to overheat. There should be no
combustible construction above the grill within 6 feet.
The installation of your grill must conform to local codes or, in
the absence of local codes, with either the National Fuel Gas Code,
ANSIZ223, 1 or CAN/CGA-B149.1, Natural Gas Installation Code or
CAN/CGA-B149.2, Propane Installation Code.
Combustible Non-Combustible
Construction
Construction
Sides
12”
0”
Back
12”
0”