12
NATURAL GAS INSTALLATION CONT.
install the gas line. A shut-off valve should be installed at the
grill. This valve must be C.S.A. Design Certified.
The grill and shut-off valve must be disconnected from the
gas supply piping system during any pressure testing of the
system at test pressures in excess ½ PSIG (3.5 KPa).
Gas Leak Test:
WARNING: Do not use open flame to perform leak test!
WARNING: Do not attempt to use grill when you smell gas or
fail a gas leak test.
When gas leak test is performed, no open flame can be
present near grill. Test for leaks every time gas connection is
disconnected.
1. Turn all controls off.
2. Open gas supply valve. Apply soapy water solution to
all connections including factory connections.
3. If any bubbles can be seen, close valve and tighten the
connection where bubbles appeared. Then repeat
steps 1 and 2: Do not over-tighten connections.
4. Grill can now be operated.