background image

12  |  

User Guide  |  Working with the Simulator  |

5.  Right  Breast  #3:  This  breast  shows  a 

retracted  nipple  with  “orangeskin”  effect, 

and on careful palpation, a mass can be felt 

immediately  under  the  nipple.    The  breast 

represents  a  carcinoma  in  one  of  the  milk 

ducts. 

6.  Left Breast #3:  This form of breast cancer 

(scirrhus  carcinoma)  is  one  of  the  more 

commonly  encountered  malignant  tumors 

of  the  breast.    When  palpating,  note  the 

infiltrating nature of the growth.  It has no well-

defined borders and cannot be moved within 

the breast. 

Right  breast  showing  a  retracted  nipple  with 

“Orangeskin”  effect,  and  Left  Breast  with 

Scirrhus Carcinoma.

Right Breast

Number

Diameter (mm)

Benign Tumor

R1

20mm

Left Breast

Number

Diameter (mm)

Malignant 

Infiltrating 

Tumor

L1

30mm

3.  Right  Breast  #2:  This  breast  shows  a 

comparatively  rare  but  palpable  tumor:  a 

giant sarcoma (or giant mammary myxoma) 

of  which  the  wildly  growing  masses  can 

be  easily  felt.    The  Giant  Sarcoma  can  be 

palpated in the lower outer quadrant, and the 

sarcomas,  including  a  columnar  mass,  are 

scattered within the upper quadrants.

4.  Left  Breast  #2:    This  breast  shows  one  of 

the  most  common  types  of  benign  growths 

(fibroadenomas) for women under the age of 

30. Three fibroadenomas varying in size from 

10-16mm  and  an  additional  20mm  benign 

tumor are scattered around the breast.

Right  Breast  with  Giant  Sarcoma  and  wildly 

growing  masses  and  Left  Breast  with  benign 

growths.

Right Breast

Number

Diameter (mm)

Giant Sarcoma

R1

25mm

Sarcoma

R2, R3

10mm

Sarcoma

R4, R9

20mm

Sarcoma

R5, R6

12mm

Sarcoma

R7, R10 15mm

Sarcoma, 

Columnar

R8

15mm

Left Breast

Number

Diameter (mm)

Smaller 

Fibroadenoma

L1

11mm

Benign Growth

L2

25mm

Larger 

Fibroadenoma

L3, L4

15mm

Summary of Contents for S230.40

Page 1: ...cal Gaumard Simulators for Health Care Education The Breast Palpation Simulator For Clinical Teaching is an interactive educational system developed to assist a certified instructor It is not a substitute for a comprehensive understanding of the subject matter and not intended for clinical decision making Teaching S230 40 ...

Page 2: ...2 User Guide Breast Palpation Simulator For Clinical Teaching ...

Page 3: ...ral 5 Storage 5 Cleaning 5 Getting Started Overview 7 Appearance of the simulator 7 Other 7 Contents 7 Terminology 7 Equipment Set Up Breast Assembly 9 Positioning 9 Working with the Simulator Instructions For Use 11 Breast Pathology 11 Description Of Included Breasts 11 Appendix Replacement Parts List 14 ...

Page 4: ...4 User Guide Care and Cautions Care and Cautions ...

Page 5: ...ese products could damage or stain the skin of the simulator STORAGE Improper storage may damage the simulator Keep it stored in the box and or bag provided Store the simulator with the breasts facing upwards in the carrying case provided Store the simulator in a cool dry place Extended storage should be between 32 85 degrees F 0 29 Celsius Other temperatures will cause the simulator to soften and...

Page 6: ...6 User Guide Getting Started Getting Started ...

Page 7: ...tinct textures useful in recognizing normal and abnormal conditions As such the simulator provides an excellent platform on which trainees can learn how to perform a breast examination as well as demonstrate breast self examination to women who want to learn how to do it APPEARANCE OF THE SIMULATOR The simulator consists of an adult upper torso with interchangeable right and left breasts including...

Page 8: ...8 User Guide Equipment Set Up Equipment Set Up ...

Page 9: ...reasts gently lift up each breast until your fingers touch the Velcro attachment then remove the breast by separating it from the torso When removing the breast from the torso do not apply force directly to the breast tissue 3 Please ensure that the torso is clean and that nothing will obstruct the placement of the breasts 4 Align and gently press the breast s Velcro strip onto the torso s Velcro ...

Page 10: ...10 User Guide Working with the Simulator Working with the Simulator ...

Page 11: ...d within both the mammary and axilla regions DESCRIPTION OF INCLUDED BREASTS 1 Right Breast 1 Normal 2 Left Breast 1 This breast represents in a slightly exaggerated form various stages of fibrocystic disease chronic mastitis which is due to an endocrine imbalance and may be found in many normal women There are six discreet fibrocystic nodes on the lower outer quadrant and a somewhat larger node o...

Page 12: ...L1 30mm 3 Right Breast 2 This breast shows a comparatively rare but palpable tumor a giant sarcoma or giant mammary myxoma of which the wildly growing masses can be easily felt The Giant Sarcoma can be palpated in the lower outer quadrant and the sarcomas including a columnar mass are scattered within the upper quadrants 4 Left Breast 2 This breast shows one of the most common types of benign grow...

Page 13: ... Appendix User Guide 13 Appendix ...

Page 14: ... wildly growing masses with carrying bag S230 40 853R 3 Right Breast 3 Retracted nipple with orange skin effect with carrying bag S230 40 853L 1 Left Breast 1 Chronic Mastitis with carrying bag S230 40 853L 2 Left Breast 2 Benign Growth with carrying bag S230 40 853L 3 Left Breast 3 Scirrhus Carcinoma with carrying bag S230 40 870 Adult Upper Torso Adult Upper Torso with carrying bag ...

Page 15: ...able Any subsequent purchasers or users of the product acquire the product as is and this limited warranty does not apply This limited warranty applies only to the products manufactured and produced by Gaumard This limited warranty does not apply to any products provided along with the Gaumard product that are manufactured by third parties For example third party products such as computers desktop...

Page 16: ... USA Office hours Monday Friday 8 30am 4 30pm EST GMT 5 4 Summer Time General Information Gaumard ZOE Michelle Mike PEDI Susie Simon Susie Simon Code Blue SIMA Models SIMA GYN AID Virtual Instruments Codemaker Code Blue NOELLE Simulation Made Easy HAL eCPR Zack RITA Chloe Seatbelt Susie Krash Kids Premie UNI Omni SmartSkin are Trademarks of Gaumard Scientific Company 2014 All rights reserved Gauma...