GT510 ATF System Service Centre

6

Operations

Note:

1/ Do not fill the ATF/ Detergent into machine during the unit is in operation.

2/ Please remove the used fluid from the tank of the machine timely after Exchange.

3/ Do not turn off the engine during the unit is in Exchange.

4/ The operator must be nearby the machine during the unit working.

1. Preparation

1.1Jack vehicle

Jack the vehicle to get the drive wheel off the ground at least 200mm, draw the brake handle

and add stop wheel ware before and after carrying wheel. Refer Fig.3

Fig.3

1.2 Connecting hose

1)

Locate a fluid hose that is connected to the radiator and transmission at the most

convenient location and then disconnect the adaptor. Locate a matched connector inside

box and connect it to the disconnected adapter.

2)

Connect the two hoses marked “TO TRANSMISSION” of GT510 to the disconnected two

ends of the hoses of automatic transmission (no consideration of the fluid flow). Refer to

Fig.4.

Fig.4

Summary of Contents for GT510

Page 1: ...GT510 ATF System Service Centre GT510 ATF System Service Centre...

Page 2: ...omplex etc Keep the unit in a well ventilated work area when performing operation and wear safety goggles respirator and clothes The operator should keep away from the heat parts such as exhaust hoses...

Page 3: ...n 7 1 4 Check up 7 2 FILLING LIQUID 7 2 1 Filling detergent 7 2 2 Adding new fluid 7 3 ATF EXCHANGE 7 4 ADJUSTING FLUID LEVEL 8 4 1 Increase fluid amount 8 4 2 Decrease fluid amount 8 5 EMPTY NEW FLUI...

Page 4: ...tification and intelligent switch the in out fluid flow direction Circulating cleaning for automatic transmission Automatic exchange of new used fluid Isothermal exchange of new used fluid Intelligent...

Page 5: ...System Service Centre 4 Structure 1 Outline Fig 1 1 Pressure Gauge 2 Sight indicator of new Used fluid 3 Operation Panel 4 Inlet Outlet pipeline 5 Detergent bottle 6 Power cable 7 Drain fluid port 1 5...

Page 6: ...IGHT arrow Set parameter Item select DOWN arrow UP arrow Item select ENTER Confirm key Parameter confirm Function execute EXIT Return key Exit key Exit function Service function Exchange ATF Adjust fu...

Page 7: ...vehicle to get the drive wheel off the ground at least 200mm draw the brake handle and add stop wheel ware before and after carrying wheel Refer Fig 3 Fig 3 1 2 Connecting hose 1 Locate a fluid hose t...

Page 8: ...hen the exchange is completed the unit will alarm and it enters the circulating cleaning state 7 If there is no used fluid into the old tank of the unit keeping 40 seconds the unit will alarm and plea...

Page 9: ...is empted 6 System setting 1 Select the system setting function 2 Select each function to operate 6 1 Parameter setting Language English and Chinese Unit metric Imperial and U S 6 2 Calibration 1 New...

Page 10: ...to each connection to check if there is any leakage during fluid exchange When any leak is found stop the GT510 immediately and check for the unit Start to exchange fluid again after reconnection is...