GATmatic GT510 User Manual Download Page 2

GT510 ATF System Service Centre

1

Safety

Read all service procedures and precautions, installation instructions and equipment operating

manuals thoroughly. Failure to observe these precautions, or the improper use of equipment,

could result in property damage, serious injury or death. Never allow improperly trained

personnel to perform these procedures or operate equipment.

Read and understand the User’s Manual before attempting to operate the GT510.

Prohibit running the EXCHANGE or ADD function before connecting to the vehicle.

Do not smoke in proximity to the machine while it is in operation.

Do not use the machine in proximity to sources of heat and fire.

Do not expose to direct sunlight or rain, use in well-ventilated work area only.

Turn off the power after the operation is completed.

When it is in operation, keep the hoses away from rotating elements and hot parts such as

cooling fans, radiators, etc.

Vehicle exhaust includes various poisonous and harmful gases (such as carbon monoxide,

hydrocarbon, nitrogen oxygen complex, etc.). Keep the unit in a well ventilated work area

when performing operation and wear safety goggles, respirator and clothes.

The operator should keep away from the heat parts such as exhaust hoses and radiator to

avoid the personal injury.

When disconnecting any connector of the pressurized fuel pipe, wrap the connector with

towel to prevent the fuel from spurting out.

The children and mental retardation personnel should keep away from the unit during

operation.

The operator should be quite familiar with the shift of automatic transmission to avoid

transmission damage caused by improper operation.

Always make the drive wheels hanging when cleaning the transmission or exchanging fluid.

The unit should be placed vertically and should not be placed upside down.

When changing fluid, the operation should be performed by properly trained personnel. The

quality of the selected ATF must conform to the direction as specified in the manual of the

auto to be operated. Otherwise, we shall not be liable for any direct or consequential

damages.

Note: specifying operations that require attention when operating the equipment.

Warning: Specifying a possible hazard that could result in damage to the

machine or personal injury.

Summary of Contents for GT510

Page 1: ...GT510 ATF System Service Centre GT510 ATF System Service Centre...

Page 2: ...omplex etc Keep the unit in a well ventilated work area when performing operation and wear safety goggles respirator and clothes The operator should keep away from the heat parts such as exhaust hoses...

Page 3: ...n 7 1 4 Check up 7 2 FILLING LIQUID 7 2 1 Filling detergent 7 2 2 Adding new fluid 7 3 ATF EXCHANGE 7 4 ADJUSTING FLUID LEVEL 8 4 1 Increase fluid amount 8 4 2 Decrease fluid amount 8 5 EMPTY NEW FLUI...

Page 4: ...tification and intelligent switch the in out fluid flow direction Circulating cleaning for automatic transmission Automatic exchange of new used fluid Isothermal exchange of new used fluid Intelligent...

Page 5: ...System Service Centre 4 Structure 1 Outline Fig 1 1 Pressure Gauge 2 Sight indicator of new Used fluid 3 Operation Panel 4 Inlet Outlet pipeline 5 Detergent bottle 6 Power cable 7 Drain fluid port 1 5...

Page 6: ...IGHT arrow Set parameter Item select DOWN arrow UP arrow Item select ENTER Confirm key Parameter confirm Function execute EXIT Return key Exit key Exit function Service function Exchange ATF Adjust fu...

Page 7: ...vehicle to get the drive wheel off the ground at least 200mm draw the brake handle and add stop wheel ware before and after carrying wheel Refer Fig 3 Fig 3 1 2 Connecting hose 1 Locate a fluid hose t...

Page 8: ...hen the exchange is completed the unit will alarm and it enters the circulating cleaning state 7 If there is no used fluid into the old tank of the unit keeping 40 seconds the unit will alarm and plea...

Page 9: ...is empted 6 System setting 1 Select the system setting function 2 Select each function to operate 6 1 Parameter setting Language English and Chinese Unit metric Imperial and U S 6 2 Calibration 1 New...

Page 10: ...to each connection to check if there is any leakage during fluid exchange When any leak is found stop the GT510 immediately and check for the unit Start to exchange fluid again after reconnection is...