background image

GT510 ATF System Service Centre

5

2. Control panel

The control panel is shown as in Fig.2.

Fig.2

Description:

ICON

NAME

DESCRIPTION

LEFT arrow、RIGHT arrow

Set parameter、Item select

DOWN arrow、UP arrow

Item select

ENTER

Confirm key

Parameter

confirm,

Function

execute

EXIT

Return key、Exit key

Exit function

Service function

Exchange ATF

Adjust function

Quantify adjust fluid amount of

AT system

Empty fluid tank

Empty new fluid tank/used fluid
tank

System setting

Set parameter of system

Summary of Contents for GT510

Page 1: ...GT510 ATF System Service Centre GT510 ATF System Service Centre...

Page 2: ...omplex etc Keep the unit in a well ventilated work area when performing operation and wear safety goggles respirator and clothes The operator should keep away from the heat parts such as exhaust hoses...

Page 3: ...n 7 1 4 Check up 7 2 FILLING LIQUID 7 2 1 Filling detergent 7 2 2 Adding new fluid 7 3 ATF EXCHANGE 7 4 ADJUSTING FLUID LEVEL 8 4 1 Increase fluid amount 8 4 2 Decrease fluid amount 8 5 EMPTY NEW FLUI...

Page 4: ...tification and intelligent switch the in out fluid flow direction Circulating cleaning for automatic transmission Automatic exchange of new used fluid Isothermal exchange of new used fluid Intelligent...

Page 5: ...System Service Centre 4 Structure 1 Outline Fig 1 1 Pressure Gauge 2 Sight indicator of new Used fluid 3 Operation Panel 4 Inlet Outlet pipeline 5 Detergent bottle 6 Power cable 7 Drain fluid port 1 5...

Page 6: ...IGHT arrow Set parameter Item select DOWN arrow UP arrow Item select ENTER Confirm key Parameter confirm Function execute EXIT Return key Exit key Exit function Service function Exchange ATF Adjust fu...

Page 7: ...vehicle to get the drive wheel off the ground at least 200mm draw the brake handle and add stop wheel ware before and after carrying wheel Refer Fig 3 Fig 3 1 2 Connecting hose 1 Locate a fluid hose t...

Page 8: ...hen the exchange is completed the unit will alarm and it enters the circulating cleaning state 7 If there is no used fluid into the old tank of the unit keeping 40 seconds the unit will alarm and plea...

Page 9: ...is empted 6 System setting 1 Select the system setting function 2 Select each function to operate 6 1 Parameter setting Language English and Chinese Unit metric Imperial and U S 6 2 Calibration 1 New...

Page 10: ...to each connection to check if there is any leakage during fluid exchange When any leak is found stop the GT510 immediately and check for the unit Start to exchange fluid again after reconnection is...