Instructions for INDUS-E SERIES Industrial Door Operator
www.gatexpertstore.com
9
gr
ee
n
re
d
ye
ll
ow
wh
it
e
Wiring of Single Phase Operator
1
——
Motor Wire: U(blue)
V(brown)
W(black)
2
——
Encoder Wire: GND(white)
A(yellow)
B(red)
VCC(green)
3
——
AC220V(single phase) Power Supply Wire
Note: Please make sure the wirings are tight and in good connection. After wiring,
remember to tighten up the IP plug to ensure all wirings completely fixed.
Warning: Please ensure the power supply wire is not plugged before you finish
all wirings.