Instructions for INDUS-E SERIES Industrial Door Operator
www.gatexpertstore.com
20
D
C
B
A
Alarm lamp
220V Alarm lamp
Two doors interlock
Control unit 1
Control unit 2
8. Relay terminal output: default is NO, if require NC type, please modify the setting of
“P3-F1” or “P3-F2”to be “1”. Output logic function can be selected under “P3-F3” and
“P3-F4”.
9. Two doors interlock: connect terminal “ILIN”of control unit 1 to terminal “ILOUT” of
control unit 2. Connect terminal “ILOUT”of control unit 1 to terminal “ILIN” of control
unit 2. Connect terminal “COM” of control unit 1 to terminal “COM” of control unit 2.
Please remember to change the parameter of “P3-F5” to be 1 if you enable this two
doors interlock function.
10. 220V alarm lamp terminal: Alarm lamp should be 220V, wire to D1 and D2
terminals.
Remote Control Password Setting
a
、
Remote control pairing:
Press AN button on the receiver, LED light will flash once, press any one of the
buttons on the remote (normally button A), LED light will flash for 4 seconds then off,
remote control pairing is complete.
If require to pair another remote control please repeat the above pairing steps, each
PC board can be paired with 25 remote controls in max.
AN
LED
Pairing Button