background image

Instructions for INDUS-E SERIES Industrial Door Operator

www.gatexpertstore.com

10

gre

en

re

d

ye

ll

ow

wh

it

e

Wiring of Three Phases Operator

1

——

Motor Wire: U(blue) V(brown)

W(black)

2

——

Encoder Wire: GND(white)

A(yellow)

B(red)

VCC(green)

3

——

AC380V(three phases) Power Supply Wire

Note:
1. Please make sure the wirings are tight and in good connection. After wiring,
remember to tighten up the IP plug to ensure all wirings completely fixed.
2. Please notice the phase sequence change when reconnecting wires. If the
phase sequence changed, the motor will run in opposite. The digital screen
won’t display abnormal if the phase sequence is correct.
Warning: Please ensure the power supply wire is not plugged before you finish
all wirings.

Summary of Contents for INDUS-E Series

Page 1: ...INDUSTRIAL DOOR OPERATOR WITH ELECTRONIC LIMIT SWITCH USER MANUAL INDUS E SERIES Website www gatexpertstore com E mail sales gatexpertstore com...

Page 2: ...ce for free or replace for free 4 The malfunction and damages caused by incorrect use or man fault is not covered by this warranty CONTACT US E mail sales gatexpertstore com Please fill in the order i...

Page 3: ...hould be installed on the wall or a post of 1 4 meters away from the ground where the operation of door can be observed to prevent children from inadvertently touching Keep the remote control well do...

Page 4: ...GUIDE OF INDUSTRIAL DOOR OPERATOR 4 4 INDUSTRIAL DOOR OPERATOR WIRING 8 5 OPERATION INTERFACE ILLUSTRATION 11 6 OPEN AND CLOSED LIMIT SWITCH SETTING 12 7 WORKING MODE SETTING 15 8 DIP SWITCH SETTING...

Page 5: ...E INDUS100SE INDUS150SE Rated Power 400W 550W 750W Torque 60N m 100N m 150N m Max gate area 30m2 40m2 50m2 No load Continuous Running Time 15 min Other Parameters Thermal Protection Temperature 120 Re...

Page 6: ...Available Optional Partial Opening Button Switch Terminal Available Optional Available Optional Interlock Terminal Available Optional Available Optional Infrared Photocell Terminal Available Optional...

Page 7: ...E SERIES Industrial Door Operator www gatexpertstore com 3 1 Electronic limit switch part Gearbox Plastic cover Wiring terminals Door operator Adjusting screw Hand pulled chain Component Control Unit...

Page 8: ...hain drive installation The factory standard configuration is for shaft drive installation If users require chain drive type they can choose the appropriate sprocket chain accessories for installation...

Page 9: ...e consistent with the opening and closing direction of the industrial door operator Step 2 Determine the installation position Consider the boundary dimension and installation direction of the door op...

Page 10: ...talling the door operator Install a fixing sleeve on door shaft first and insert the industrial door operator into the door shaft Step 4 Pre fix the industrial door operator Fix the industrial door op...

Page 11: ...ned with the key slot of the door shaft Note When releasing the hand pulled chain make sure that the hand pulled chain has been reset successfully Step 6 Mount the flat key and fixing sleeve Mount the...

Page 12: ...ructions for INDUS E SERIES Industrial Door Operator www gatexpertstore com 8 Industrial Door Operator Wiring Wiring Between Door Operator and Control Unit 1 Motor Wire 2 Encoder Wire 3 Power Supply W...

Page 13: ...lue V brown W black 2 Encoder Wire GND white A yellow B red VCC green 3 AC220V single phase Power Supply Wire Note Please make sure the wirings are tight and in good connection After wiring remember t...

Page 14: ...ply Wire Note 1 Please make sure the wirings are tight and in good connection After wiring remember to tighten up the IP plug to ensure all wirings completely fixed 2 Please notice the phase sequence...

Page 15: ...Door Operator www gatexpertstore com 11 OPEN CLOSE STOP OPEN CLOSE STOP Operation Interface Illustration STOP DOWN DIGITAL SCREEN UP INDICATOR LIGHT REDUCE INCREASE CONFIRM NEXT Opening status display...

Page 16: ...ing OPEN CLOSE STOP After powering on the digital will display E 03 hasn t set the limit switch OPEN CLOSE STOP Press and hold NEXT for 3 seconds the digital will display 00000 OPEN CLOSE STOP OPEN CL...

Page 17: ...press confirm once again The digital will display Shortly press OPEN to check opening direction if it s correct then press and hold OPEN to set the open limit switch position digital will flash If th...

Page 18: ...digital will display the encoder value for 1 second and then show then you can set the closed limit switch position Press and hold CLOSE to set the closed limit switch position until the gate runs to...

Page 19: ...hould be 1 4 high from the ground to keep it away from Children DIP Switch Setting ON Up Position OFF Down Position No 1 ON Mechanical Limit Switch OFF Electronic Limit switch No 2 No function No 3 No...

Page 20: ...P1 F3 Pre stop before arriving at the closed limit switch position 0 200 60 P1 F4 Delay time for Auto close 0 120 sec 10 P1 F5 Height of partial opening 0 100 50 P1 F6 Inch move for opening 0 Continuo...

Page 21: ...ght of airbag valid 1 1500 50 P3 F8 Locked rotor time 1 7 4 P3 F9 Restore to factory setting of P3 0 No 1 Yes 0 P4 P4 F1 Alarm of running over the open limit switch 10 200 80 P4 F2 Alarm of running ov...

Page 22: ...d NC type please modify the setting of P2 F1 to be 1 2 External partial opening button switch terminal terminal type is NO if you need NC type please modify the setting of P2 F2 to be 1 The height of...

Page 23: ...photocell can be adjusted under P3 F6 5 Safety airbag terminal There are 2 signal types of safety airbag level signal and pulse signal factory default is level single in NO type if require NC type or...

Page 24: ...of control unit 2 Connect terminal COM of control unit 1 to terminal COM of control unit 2 Please remember to change the parameter of P3 F5 to be 1 if you enable this two doors interlock function 10 2...

Page 25: ...ic use of the industrial door operator When the hand pulled chain is not in use please fix the hand pulled chain to the wall in the appropriate way When using a period of time if the chain can not smo...

Page 26: ...ith a multimeter which phase is lost and re wire 3 E 02 Encoder disconnect Encoder was not connected or wrongly connected Re connect the encoder 4 E 03 Limit switch abnormal Up and down limit switch w...

Page 27: ...INDUS100SE INDUS150SE No Name Qty Note 1 Door operator 1 2 Mounting bracket 1 3 Fixing sleeve 2 Contain M6 10 fastening screw 4 Special flat key 1 6 70 5 Hexagon bolts 4 M10x20 7 User manual 1 8 Motor...

Reviews: