T1 CrossConnect Installation & Operation Manual
6 – Configuration Using ISiCL
Version 2
6-6
GatesAir
Intraplex Products
Note that the
*OK
in the first line of the response indicates that the received command was valid, not
that the DCS is “okay.”
6.10 DCS SET Parameters
6.10.1 DCS SET Command Use
The setup of a DCS chassis can be changed by issuing
SET
commands with the appropriate parameter
names and values. The key is to include the
DCS
value in the subaddress field of the command line.
For example, to set the recovery time to 0.1 second of a DCS connected to a multiplexer at address
32, issue this command:
32:DCS:SET:REC=0.10;
Table 6-2 lists the valid DCS:SET: parameters that can be changed remotely.
Note:
CrossConnect products shipped before November 1, 1999 only respond to the command
:DACS:SET:
while products shipped after that date respond to either
:DCS:SET:
or
:DACS:SET:
commands.
Table 6-2. Valid
:DCS:SET:
Parameters and Legal Values
Parameter
Function
Legal Value
Sets Parameter To
ACT1
Port 1 active/
not active
ON
Port 1 in service
OFF
Port 1 not in service
ACT2
Port 2 active/
not active
ON
Port 2 in service
OFF
Port 2 not in service
ACT3
Port 3 active/
not active
ON
Port 3 in service
OFF
Port 3 not in service
ACT4
Port 4 active/
not active
ON
Port 4 in service
OFF
Port 4 not in service
ACT5
Port 5 active/
not active
ON
Port 5 in service
OFF
Port 5 not in service
ACT6
Port 6 active/
not active
ON
Port 6 in service
OFF
Port 6 not in service
ADDR
Shelf address
1 – 63
Sets CM-95 shelf address
BER
Bit error rate
10
-6
to 10
-3
Bit error rate
CLOCK
Clock source
Alt1, Alt2
Alt1 = Alternate Clock 1 (I (Internal), E (External), 1-6)
Alt2 = Alternate Clock 2 (1 to 6) (optional)
CODE, P
T1 line code
AMI
Alternate Mark Inversion
P – port number (1 to
6)
B8ZS
High Density Bipolar
DLY1
Delay
0 to 100 (ms)
Switch time delay, port 1
DLY2
Delay
0 to 100 (ms)
Switch time delay, port 2
DLY3
Delay
0 to 100 (ms)
Switch time delay, port 3
DLY4
Delay
0 to 100 (ms)
Switch time delay, port 4
DLY5
Delay
0 to 100 (ms)
Switch time delay, port 5