background image

 
 

page 27 

of the Control Board, will begin flashing quickly.  After about 75 seconds, the gate will 
begin moving on its own as it begins learning its travel path.   
 
The learning mode executes as follows: 
 

1.

 

Master Gate Closes (actuator extends) 

2.

 

Master Gate Opens (actuator retracts) 

3.

 

Master Gate Close (actuator extends) 

 
At this point, you should verify the direction that the gate is opening/closing the gate, as 
you want.  That the gate is closing in the direction you want it closed (steps 1 and 3 
above), and opens in the direction you want it to open.   
 
If the gate does not move in the desired direction, then you will need to reverse the motor 
operating direction.  To change the operating direction, swap the black and white wires 
from J1 Master and J2 Slave. 

Two Gate Operation 

For a two-gate installation, the first time you click the Remote Control Button 1, the 
Control Box will receive the signal and initiate a small red light, located about the middle 
of the Control Board, will begin flashing quickly.  After about 75 seconds, both gates 
begin moving individually as they each learn their travel path.   
 
The learning mode executes as follows (this example is Pull to Open): 
 

1.

 

Slave Gate Closes (actuator extends) 

2.

 

Master Gate Closes (actuator extends) 

3.

 

Master Gate Opens (actuator retracts) 

4.

 

Slave Gate Opens (actuator retracts) 

5.

 

Slave Gate Closes (actuator extends) 

6.

 

Master Gate Closes (actuator extends) 

 
At this point, verify the direction that the gates open and close is correct and that the 
gates are opening and closing in the correct sequence.     
 
If the gates do not move in the desired direction, then you will need to reverse the motor 
operating direction.  To change the operating direction, swap the black and white wires 
from J1 Master and J2 Slave. 

Pedestrian Start Feature:  

The System can be set to open only one side of the gate for pedestrian traffic: 
 
For a dual gate, connect the motor cables for both terminals J1 & J2.  Press the green 
button of the transmitter to activate Pedestrian Start. 
 
For a single gate, connect the motor cable for terminal J1 only.  Press the black button of 
transmitter to activate Pedestrian Start. 

Summary of Contents for YG-5602

Page 1: ...YG 5602 1U E Swinging Gate Owner s Manual...

Page 2: ...YG 5602 1U E Swinging Gate Owner s Manual Version 4 2014 Gatekeeper Ltd P O Box 752 Lacey s Spring AL 35754 www gatekeeperltd com Latest version available at www gatekeeperltd com YG5602UE_User_Manua...

Page 3: ...irection 15 Pull to Open Inward 16 Push to Open Outward 17 Stopper and Latch Installation 18 Stoppers without Electric Latch 18 Stoppers with Electric Latch 18 Electric Lock Cross Section 19 Electrica...

Page 4: ...ion 31 DIP Switches 32 Auto close function DIP Switch 4 5 32 Additional Features 33 Maintenance Guide Mechanical Maintenance 36 Symptoms Solutions 36 Gatekeeper Specifications 38 Gate Arm Actuator Par...

Page 5: ...tekeeper YG meets all Underwriters Laboratories UL 325 Safety Standards to help reduce the risk of gate related accidents It also meets the UL Fourth Edition standard requiring any automatically openi...

Page 6: ...key release Operation Adjustable output thrust Adjustable operating time 12 seconds 100 seconds Time delay protection Adjustable auto close child safety obstruction sensitivity Self locking and rever...

Page 7: ...page 7 YG 5602 1U E Swinging Gate Installation Guide...

Page 8: ...while it is moving Do not pass through gate until all motion is completed Do not allow children or pets near your gate Keep remote controls away from children Place controls where they cannot be reach...

Page 9: ...oth gates can move freely Do not install the Gatekeeper YG on gates that move up or down slope Conduit Use PVC conduit to protect the electrical wires that power the Gatekeeper YG You may need to pres...

Page 10: ...l to calculate the voltage drop There must be a 15A circuit breaker installed between the Gatekeeper YG Control Box and the power source Solar Power If you plan to use solar panels to power your gate...

Page 11: ...he Gatekeeper YG Open the box and carefully remove the items Place the items on trays or a tarp so that you can verify the contents Mark each item opened as Received Qty Rcd Item 2 Actuator Arm Assemb...

Page 12: ...12 Qty Rcd Item 1 Antenna 1 Key Switch 1 Button Switch 2 RF Opener Fobs 3 Set of Two Keys 2 Bracket Assembly 2 T Bracket 1 L Bar 1 Z Bracket 2 Cotter Pins Cotter Pin Bolts 2 Antenna Plate Mounting Sc...

Page 13: ...u received all of the parts above If you are missing something please check the box and the packaging materials carefully Some of these items are small and can be easily lost If you are definitely mis...

Page 14: ...are within specified levels The gates swing freely You have adequate electrical power at the installation site You have all required permits You have verified the contents of the shipping box If any r...

Page 15: ...First aid kit Installation instructions Gate Arm Actuator Installation The YG 5602 gate operator operates by forcing a worm gear to extend inside each actuator pushing or pulling the gate open Instal...

Page 16: ...0 degrees from it Mount the actuator so that the key slot is on top of the arm Open the gate and lock the actuator with the key Pull to Open is the most common configuration for an entry gate Opening...

Page 17: ...m so that the key slot is on top of the actuator Then lock the actuator with the key Push to Open Outward is the best configuration for exit gates Do not use Push to Open Outward with entry gates beca...

Page 18: ...s without Electric Latch Install Stopper 1 stops gate in closed position Install Stoppers 2 stops gate in maximum opened position Stoppers with Electric Latch Install the Electrical Latch and the Slav...

Page 19: ...e Gate Stopper The Electric Lock attaches to the slave gate and contacts the Stop Block The L Bar is welded to the master gate ensuring the master gate lines up with the slave gate when closed The Bar...

Page 20: ...box and is included for your information Connecting the AC Power The Control Box must have a single phase circuit breaker 15A between the Control Box and the power source CAUTION Be sure that the rock...

Page 21: ...hot usually black wire to the middle terminal c Wire the neutral usually white wire to the terminal on the right 2 Verify that all electrical connections are waterproof by installing electrical outle...

Page 22: ...connections used during installation F1 fuse maximum 0 5A PCB F2 fuse maximum 15A Over current SW2 Used to program the remote controls to the board VR1 Over current limit can be adjusted from min 3 5A...

Page 23: ...al and Power Ground for external devices J4 13 Positive Supply 12V DC J4 14 15 Photo Sensor contacts must be shorted together if no photocell J5 16 Aerial Antenna Cable connect to aerial for increased...

Page 24: ...for the 12 V DC Positive and Gnd Negative J4 Terminal block 10 Connect to the push button or external receiver board for the dual gate operation J4 Terminal block 11 Connect to the push button or exte...

Page 25: ...W2 Code Learn on the Control Board You will notice that an LED turns on the control board indicating that the RF Remote Learning Mode is active During the RF Remote Learning Mode period press Button 1...

Page 26: ...wer light will turn on During the system learning mode two situations must be corrected using the Variable Register VR1 screw over current sensitivity obstruction sensor on the Control Board 1 One lea...

Page 27: ...trol Board will begin flashing quickly After about 75 seconds both gates begin moving individually as they each learn their travel path The learning mode executes as follows this example is Pull to Op...

Page 28: ...or normal use Use the following chart to interpret what the system is telling you Quick flashing light Systems operation is at slow down speed or the system is in learning mode kickback extra push ph...

Page 29: ...ate If the gate is moving then activating the keypad will stop the gate The keypad device can be obtained through your dealer To find a dealer go to the Gatekeeper Ltd website and look under Dealers L...

Page 30: ...ve photocells require power on both sides of the driveway whereas passive photocells employ a reflector plate so that power is only required on one side of the driveway Most photocells will provide DC...

Page 31: ...in the gate s path Verify that when the strikes the object the alarm sounds and the gate reverses motion Do not use yourself a pet or a child to test the auto reverse function The gate can cause serio...

Page 32: ...The SM2 slave leaf start delay can be adjusted between 0 seconds and 8 seconds by turning the screw DIP Switches Auto close function This feature allows the gate to stay open for 15 25 or 50 seconds b...

Page 33: ...arts moving at same time OPENING PHOTO When the gate is moving at opening phase the photo sensor can be selected as active or inactive ON If photo sensor covered by the obstacle during the gate openin...

Page 34: ...page 34 This page intentionally left blank...

Page 35: ...page 35 YG 5602 1U E Swinging Gate Maintenance Guide...

Page 36: ...f the battery is less than 10 5 VDC 3 Check the LED used for push button is lit 4 Check fuses at power source 5 Turn the power off disconnect J7 J8 for 30 seconds then turn it back on and repeat the l...

Page 37: ...mediately stop at end of travel Adjust the VR1 to decrease the over current limit Reread Auto reverse Function on page 31 Flashing light does not work Check the wiring of the flashing light to make su...

Page 38: ...ure Range 20 C 55 C 4 F 131 F Power Consumption 150W Max 5W Standby Power Supply of the Motor 12VDC 8A 96W MAX Power Supply of the Lamp 12VDC 21W MAX Power Supply of the Electric Lock 12VDC 60W Max Po...

Page 39: ...r to your gate No Description Quantity Single Dual 1 Actuator 1 2 2 Nest Pin 1 2 3 Fastener Screw 1 2 4 L Mounting Bracket 2 4 5 Bar Mounting Bracket 1 2 6 Nut for Bolt 2 4 7 Bolt 2 4 8 Release Key 1...

Page 40: ...page 40 Actuator Specifications and Measurements Actuator Maximum Direct Force 1400N 315 lbs Actuator Maximum Power Consumption 12V at 6A 72W Duty Cycle 50 30mm 1 2 30mm 1 2 75mm 2 95 100mm 3 94...

Page 41: ...er Ltd specifically disclaims any and all implied warranties of merchantability or fitness for a particular purpose It is the purchaser s sole and exclusive responsibility to determine whether or not...

Page 42: ...atekeeperltd com For updated versions of the manual see www gatekeeperltd com YG5602UE_User_Manual pdf For Additional Remotes Infrared Photo Cells or parts please contact your dealer www gatekeeperltd...

Reviews: