background image

 

 
 

Installation and Maintenance Manual

 

Sliding Gate Operators

 

Models: GDS 

Made in Australia from Australian & quality imported components

 

 

 
 
 
 

 

Installation and Maintenance Manual

Sliding Gate Operators

Models: GDS 450L & 630L Range 

Made in Australia from Australian & quality imported components

 

 

 

ABN       

July  

 

 

N14870 

 
 
 
 

Installation and Maintenance Manual 

Sliding Gate Operators 

Made in Australia from Australian & quality imported components 

 

Summary of Contents for 630L series

Page 1: ...ty imported components Installation and Maintenance Manual Sliding Gate Operators Models GDS 450L 630L Range Made in Australia from Australian quality imported components A B N July N14870 Installatio...

Page 2: ...the rack teeth and Pinion wheel Once the rack is fixed move the gate and sight the rack moving over the pinion wheel check that most of the pinion wheel meshes with the rack Make sure rack runs freel...

Page 3: ...he gate travels is in accordance with the opening and closing status LED s if not reverse two of the motor wires at the inverter terminals Inverter settings can be adjusted via the keypad i e Opening...

Page 4: ...Precautions 5 2 Wiring Requirements 6 3 Installation Details 6 10 Electrical cabling Mechanical installation Electrical connections Operator dimensions CB 6 control board layout Inputs Outputs Mode de...

Page 5: ...ateposts or mounting structure has the necessary strength and rigidity to support the operator and the load of the opening and closing gate motion Always incorporate the appropriate Photo Electric Cel...

Page 6: ...sed positions These stops need to be engineered and installed such that they will be strong enough to stop the gate should the limits fail at any time Remove the gate operator cover and position mount...

Page 7: ...7 Operator Dimensions...

Page 8: ...ver 7 Motor 2 Limit Switch Inputs no t shown 8 Terminals for Isolated 24vAC Supply 21 Firmware Version Label for Limit Switch and Control Inputs 22 Light Control Relay Interface 9 Pedestrian Access Co...

Page 9: ...din rail to switch the 12 volts to an electric lock if fitted The load switched by the lock output terminals must not exceed 30v AC DC 5Amps If a electro magnetic lock is used change one wire on the c...

Page 10: ...t also resets the P E triggered auto close mode so that the P E input will need to be triggered again before a P E auto close cycle will be initiated Position 5 M 2 OUTPUTS STATUS OFF The M2 output co...

Page 11: ...tor led s go out when the corresponding limit switch is activated If they are the wrong way around swap over the M1 op and cl limit wires They can be roughly set so they activate approx 500 to 800mm b...

Page 12: ......

Page 13: ...pened by hand To re engage the clutch move the gate by hand Into approx The half way position and turn the Knurled knob clockwise until it is very tight If when turning the knurled knob clockwise and...

Page 14: ...Failure to maintain equipment may result in injury or death and or damage to property and equipment Recommended maintenance to be performed on the operator and gate are as follows Operator performs o...

Page 15: ...ircumstances i If no proof of date of purchase can be produced ii If the product has been used in a manner beyond its design parameters iii If the product is tampered with or repaired by personnel not...

Reviews: