different: one is higher and the other is lower. Verify and if necessary exchange the
two bracket positions. MIS-INSTALLATION of this magnetic switch is the NUMBER 1
cause of trouble with this opener.
.
Gate
Nut
Bolt
Spring washer
Plain washer
Magnet bracket
Magnet
Gate operator
Magnetic limit
switch inside
Fig 8.
7. Electrical Installation
Connecting the battery (see Fig.10)
Connect the red battery lead to ‘BAT+’ terminal of control board, and black battery lead to
‘BAT-’.
Battery
BLACK WIRE TO POSITIVE-
RED WIRE TO P
Fig.10
Connecting the motor (see Fig.11)
Connect motor wires to ‘M+’ and ‘M-’ of terminal block JX4.
NOTE: all the wires above have been connected before delivery.
NOTE: The operator is only designed to work for less than 20 minutes at a time (Work duty:
S3-40%). If it runs continually for an extended period of time, the MOSFET will burn out
because of the high temperature.