Mounting the System.
Installation / Environmental Requirements.
The 508-HD has an operating temperature range of -40° C to +65° C. It is good practice to ensure that the 508-HD is mounted in
an area in which acceptable temperature ranges are experienced.
Please fully read and understand the following conditions to ensure the Warranty will not be voided.
1.
The 508-HD operates between 8V ~ 36V. Please ensure a regulated, consistent power source is available for the 508-HD.
2.
DO NOT remove any enclosures/covers associated with the 508-HD as this will void the warranty.
3.
Remove the In-Line Power fuse prior to jump starting the vehicle.
4.
Select a solid ground connection for the 508-HD.
5.
Do Not use any third party accessories, unless approved by Gatekeeper Systems.
6.
The 508-HD is designed for interior use only. Do not install in areas which are exposed to excessive moisture / wetness.
7.
Mount 508-HD in a location which has good air-flow and is not subject to excessive heat/cold variations. Allow at least 6” of
clearance all around for effective cooling of the system.
8.
Ensure that the 508-HD is mounted where it is not easily accessible by non-authorized personnel.
9.
Ensure that ALL provided Split Looms are used around exposed cables. Grommets are to be used as directed by install sheet.
Failure to use provided Split Looms and Grommets will void the warranty.
10.
Gatekeeper Systems provides Tek Screws with which to mount the 508-HD, these have been tested and are approved for
mounting.
Power Connection.
The supplied fuses MUST be used, failure to protect the system with the correct value fuse may lead to the warranty being voided.
The 1AMP fuse must be installed as close as possible to the source on the Yellow Ignition wire on CAB000359
The 15AMP fuse must be installed as close as possible to the source on the Red (+12V) wire on CAB000359
Power Connector (CAB0000359)
GND (A) Input (Black): Connect to the negative terminal of the battery, -12V.
Ignition (B) (Yellow): Connect to vehicle ignition. +12V signal required to activate the 508-HD. Ensure that the provided 1
AMP In-Line fuse is used
Positive (C) (Red): Connect to the positive terminal of the battery, +12V. Ensure that the provided 15 AMP In-Line fuse is
used