22
If you remove the pot from the device, the LEDs are flashing fast and the pot detection will turn off the
unit into the standby mode after 10min (default value for auto power off). If you put back the pot before
the auto power off, the unit will continue warming on the previously selected power level.
All inductive pots can be used with the InductWarm
®
130+.
The InductWarm
®
130+ has an integrated
temperature protection
to protect the device and the cover
material from overheating. If the default temperature of 90°C has reached, the unit automatically
reduces its power level from level 4 to level 3 (LED 4 is flashing). If the temperature still increases by
another 5°C, the device automatically changes its mode to standby mode for security purposes. A restart
is possible after the InductWarm
®
130+ has cooled down under the protection level. This can last a few
minutes.
BUS-Coupling / Network Mode
If you are using the InductWarm
®
130+ in a network, you must connect an external control unit to any
induction unit. As soon as you press the power selection button on the external remote unit, this specific
device will become “MASTER” in the network. All other devices will be “SLAVE”.
Every 3 seconds, the master-unit sends it’s the power level information to its slave-units.
If there is no pot on all units, the master unit will turn all device in standby mode after approx. 20
seconds.
(
Note: Valid „AutoPowerOff“-time for the entire network is the time set in the “master” (default 600s).
Each device must have an individual device address!)
An individual power control of one single unit is not possible anymore. The “no pot detection” (flashing
LEDs) will NOT be active in the network mode.
A maximum of 16 units can be linked together in a network.
USB Connectors
Both, software updates and system parameter updates can be loaded via the USB port. This task should
only be performed by trained service staff.